32
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
11. WARRANTY TERMS
The warranty terms are described in the Service booklet included in the supply.
12. TECHNICAL FEATURES
12.1.
Technical parameters of Dual Chamber boiler DC-A v2
Table 8. Technical parameters
MODEL
CombiBurn DC 35 А v2
Nominal heat output kW
8 ÷ 35
Min. / Max. heat output
wood pellets
wood-chips
kW
kW
8,5 ÷ 30
7,5 ÷ 28
Mass flow exhaust gases
Min. / Max. heat output
wood pellets
wood-chips
kg/s
kg/s
0,007 ÷ 0,017
0,006 ÷ 0,017
Overall dimensions of boiler, fuel
hopper and burner
Height H Width L/
Depth D
mm
mm
1600
1400 / 1070
Dual-chamber boiler
BURNiT CombiBurn
Height / Width / Depth mm
1560 / 630 / 1070
Mantle volume Liters
113
Wood - combustion chamber volume Liters
96
Pellets - combustion chamber volume Liters
72
Required chimney draught Pa/mbar
20 / 0.20
Recommended fuel
Automatic loading
Wood pellets /EN 14961-2:2011/
Automatic loading -
Alternative
Wood chips and fruit stones
Manual loading -
Alternative
wood, humidity 20%;
wood briquettes; wood + coal;
Max. length of firewood logs mm
500
Operating temperature range
/Max.temperature °С
65 ÷ 85 / 95
Exhaust gas temperature (operation mode) °С
150 ÷ 180
Max. operating pressure bar
3
Cold water inlet А, mm
G1¼”/ 460
Hot water outlet B, mm
G1¼”/ 1510
Safety heat evacuator inlet /outlet K, mm
R½”/ 1400
Flue
F, mm
J, mm
ø 180 / 1260
315
Flue cleaning /inspection/ opening O, mm
200 x 90
Loading door size N, mm
200 x 390
Upper inspection door P, mm
150 x 390
Lower inspection door R, mm
300 x 390
Removable ash and soot container V, mm
220 x 500 x 200
Transporting auger motor/ash and soot/ T, mm
135
Drain
Y, mm
R½” / 290
Control Unit
U