33
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
Burner
Heat output kW
30
Average power
consumption
Firing-Up mode
W
1600
Operate mode
W
60÷70
Self-cleaning mode
W
1300
Electric power supply V/Hz
220 AC / 50
Fuel
Hopper
Height / Width / Depth mm
1105 / 625 / 810
Fuel Hopper volume
L
265
Water tank S, Liters
10
Weight /boiler, fuel hopper, burner/ kg
610
12.2.
Elements of Dual Chamber boiler
CombiBurn DC-A v2
1. Dual-chamber boiler;
2. Fuel Hopper;
3. Auger;
4. Pellet / chips burner;
5. Control unit;
6. Safety heat evacuator;
7. Thermal wool insulation;
8. Fume exhaust tube;
9. Three-pass flue gas flow;
10. Mantle;
11. Wood - combustion chamber;
12. Metal grate;
13. Pellets - combustion chamber;
14. Ash Aand soot transport screw with stirring
mechanism
15. Removable ash and soot container;
16. Lower inspection door;
17. Loading door;
18. Upper inspection door.
Diagram 14. Elements of Dual Chamber boiler DC-A v2