31
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
buffer tank to it (depending on the
connection scheme)
(see item 10.3.4,
menu CH Mode).
-
Summer Mode
– Boiler works for
heating of domestic hot water only.
If you have selected the
(CH + DHW) option, upon
confirmation of command
via the F button you may
navigate to the next screen.
From this menu you can
set up and adjust DHW
pump activity periods.
Use the arrow keys to set
time (HH:MM). Use “Enter” button to
checkmark desired time period option. If
no option is check-marked, the controller
will maintain DHW temperature as a
priority. Only when its preset value is
reached, the CH circulation pump will start.
Important
: The use of “External
room thermostat for the burner”
option (Thermostat) is active only
if option is selected (CH Priority
– priority of central heating
installation pump).
10.2.3. Manual operating mode selection
After pressing the
“F” button, enter the
main menu and by
pressing
the
navigation arrow keys select the “
Manual
”
menu.
At this menu, we can
choose whether we
want the boiler to go
from Manual mode
to Automatic mode
(Auto). If we want this to happen, mark
the check box through the navigation
buttons. Once you choose this feature,
and the exhaust temperature of the boiler
drops below the set pint temperature in
menu
“
Setup
“, the boiler goes into
Auto
mode and the burner ignites automatically.
If you do not mark the check box, the
boiler goes off upon reaching the adjusted
temperature value of extinction, the
boiler goes off.
At this menu through
navigation arrows, you
can set priority mode of
operation of the boiler.”
CH + DHW
- In this mode both pumps
for the heating system and domestic hot
water are active.
CH only
- In this mode only the pump for
heating the heating system (CH pump) is
active.
At this menu you can
set the power of the
burner fan, at which
you want the fan to
work in
Manual
mode for inflaming the
fuel in the upper combustion chamber.
If you want to put out
the boiler, press the
“
F
” button to enter
the main menu and
through the navigation
arrow keys select the
Standby
menu and
confirm the choice by pressing “
F
”.
10.2.4. Burner shut-down „Standby“
Pressing the “
F
” button
will take you to the main
menu and by using the
navigation arrows you
can select the “
Standby
” menu and
confirm the selection by pressing “
F
”. The
burner goes into extinguishing mode. Set
the temperature to start heating pump.