temperature.
Set
maximum
temperature of the
boiler
through
navigation arrows.
Press button
F
and hold for 3 seconds to
set the follow parameters:
Possibility for forced
turn on of ash and soot
transport screw. Time
setting
of
screw
operation. To set start and operating time
use buttons
“Navigation arrow Up”
and
“Navigation arrow Down”.
After entering
the correct value press button
“Enter”
.
Use this menu to adjust
switch-on temperature
of
central
heating
pump.
From this menu you can
preset buffer tank
circulation
pump
switch-on and switch-
off temperatures provided such heating
installation scheme (with buffer tank
included) is selected, whereas the two
sensors reading these temperatures are
mounted in the upper, respectively lower
part of the buffer tank (cf. boiler
connection schemes).
From this menu you can
adjust the maximum
temperature in the
domestic hot water
storage tank, whereas by navigating from
the arrow keys up and down and using the
Enter button you can change the
parameters. You can adjust the maximum
domestic hot water temperature inside
the storage tank, as well as the switch-on
hysteresis for the circulation pump after a
drop of DHW temperature inside the
storage tank.
Use UP and DOWN
arrow keys in Set Time
menu to set the unit’s
built-in timer/clock.
Use UP and DOWN
arrow keys in Set Date
menu to set the date.
Use UP and DOWN
arrow keys in Contrast
menu to adjust the LCD
display backlight level.
Confirm settings by shifting to next
submenu through a single pressing of the
functional key F.
Use this menu to choose
the language of the
controller. Choose a
language by pressing
navigation arrows and button
“Enter”
.
10.2.2. Burner start-up „Switch mode“
Burner start-up. After
pressing the
“F”
button
and using the navigation
arrows, the “
Auto
” or
„Standby”
menu is selected.
Set the priority mode of
the burner through
“navigation arrows.”
-
CH + DHW
– Both pumps /
CH
-central
heating pump and
DHW
– domestic hot
water pump /are active.
-
CH only
– In this mode of operation the
only active pump is the
CH
circulation
pump for the heating installation
(CH
pump)
. In this mode, the boiler can
be managed via a room thermostat
or be temperature-controlled by the
temperature inside the connected