TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
1.2.3.
Minimum
clearances
for
installation
and
flammability
of
construction materials
The applicable minimum clearances in
your country may differ from the ones
specified below. Please, consult your
installer.
The minimum distance from the burner,
heating boiler or exhaust gas pipe to
objects or walls must be at least 200 mm.
Table 1. Flammability of construction
materials
Class А
– non-
flammable
Stone, bricks, ceramic tiles,
baked clay, solutions, plaster
free of organic additives.
Class B
–
hardly
flammable
Gypsum board panels,
basalt fiber needled felt,
fiberglass board, AKUMIN,
Izomin, Rajolit, Lignos, Velox,
Heraklit.
Class
С
1/
С
2 -
Medium
flammable
Wood beech, oak. Wood
softwood, layered wood
Class C3
– easy
flammable
Asphalt, cardboard, cellulose,
tar,
fiberboard,
cork,
polyurethane, polyethylene.
Diagram 1. Recommended clearances
between boiler and walls.
For general safety considerations, we
recommend that the boiler be placed on
a foundation made of class A material, see
table 1.
2. PRODUCT DESCRIPTION
The CombiBurn high-efficiency dual
chamber boiler is designated for central
heating of premises through burning of
wood pellets.
Alternative fuels:
wood chips, dry stones of
cherries, plums, apricots, crushed
stones of peach and olive stones.
Use different types of alternative
fuels separately!
The combustion of these fuels is
performed in the lower combustion
chamber by means of an integrated into it
high-performance burner. As alternative
(backup fuel) for it can be used wood
logs, wood briquettes and coal, which are
loaded to the upper boiler chamber.