3-106
Confidential
(3) Disconnect the registration front/rear sensor harness, the T1 paper feed sensor harness
and the MP paper empty sensor harness from the high-voltage power supply PCB
ASSY, and remove the high-voltage power supply PCB ASSY from the machine.
(4) Disconnect the main HVPS flat cable from the high-voltage power supply PCB ASSY.
Fig. 3-135
Harness routing: Refer to
“4.High-voltage power supply PCB ASSY”
.
Main HVPS flat cable
High-voltage power supply PCB ASSY
Registration front/rear sensor harness
T1 paper feed sensor harness
MP paper empty sensor harness
Summary of Contents for MFC-8510DN
Page 27: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 43: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Page 143: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Page 155: ...3 9 Confidential Hinge ASSY L Fig 3 7 Hinge R Legal model only Fig 3 8 ...
Page 277: ...Confidential CHAPTER 4 ADJUSTING AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Page 293: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 300: ...5 5 Confidential Fig 5 1 ...
Page 325: ...5 30 Confidential Fig 5 14 ...
Page 327: ...5 32 Confidential Fig 5 15 ...
Page 346: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Page 348: ...6 1 Confidential 1 WIRING DIAGRAM Wiring diagram ...
Page 349: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 368: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 372: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...