3-100
Confidential
9.36 Duplex solenoid
(1) Remove the eject idle gear 20 from the main frame L ASSY.
(2) Remove the eject switch arm spring from the main frame L ASSY.
(3) Remove the eject switch arm from the main frame L ASSY.
(4) Remove the eject sector gear spring from the main frame L ASSY.
(5) Remove the eject sector gear from the main frame L ASSY.
(6) Remove the taptite bind B M3x10 screw, and remove the duplex solenoid and the duplex
solenoid lever from the main frame L ASSY. Then remove the duplex solenoid lever from
the duplex solenoid.
(7) Remove the duplex solenoid spring from the duplex solenoid.
Fig. 3-129
Assembling Note:
• When attaching the eject sector gear spring and the duplex solenoid spring, pay
attention to the direction, as shown in the illustration above.
Eject switch arm
Eject switch arm spring
Main frame L ASSY
Eject sector gear
Eject idle gear 20
Duplex solenoid lever
Taptite bind B M3x10
Eject sector gear spring
Duplex solenoid spring
Duplex solenoid
Eject sector
gear
Eject sector gear spring
Duplex solenoid spring
Eject sector
gear spring
Boss
A
A
Summary of Contents for MFC-8510DN
Page 27: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 43: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Page 143: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Page 155: ...3 9 Confidential Hinge ASSY L Fig 3 7 Hinge R Legal model only Fig 3 8 ...
Page 277: ...Confidential CHAPTER 4 ADJUSTING AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Page 293: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 300: ...5 5 Confidential Fig 5 1 ...
Page 325: ...5 30 Confidential Fig 5 14 ...
Page 327: ...5 32 Confidential Fig 5 15 ...
Page 346: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Page 348: ...6 1 Confidential 1 WIRING DIAGRAM Wiring diagram ...
Page 349: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 368: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 372: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...