2-89
Confidential
4.8
Troubleshooting for Fuser Unit Problems
4.8.1 Fuser unit failure
Step
Cause
Remedy
1
Harness connection failure
between fuser unit and eject sensor
PCB
Check the harness connection between the
fuser unit and the eject sensor PCB, and
reconnect it if necessary.
2
Harness connection failure
between fuser unit and low-voltage
power supply PCB
Check the harness connection between the
fuser unit and the low-voltage power supply
PCB, and reconnect it if necessary.
3
Connection failure of the eject
sensor PCB harness
Check the connection of the eject sensor
harness, and reconnect it if necessary.
4
Eject sensor PCB failure
Refer to
"1.3.10 Check sensor operation
(function code: 32)" in Chapter 5
to check
the sensor operation. If the sensor operation
is faulty, replace the eject sensor PCB
ASSY.
5
Low-voltage power supply PCB
failure
Replace the low-voltage power supply PCB
ASSY.
6
Fuser unit failure
Replace the fuser unit.
7
Main PCB failure
Replace the main PCB ASSY.
CAUTION:
• Turn the power switch OFF and then ON again. Leave the machine for ten minutes.
This problem may then be cleared.
Summary of Contents for MFC-8510DN
Page 27: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 43: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Page 143: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Page 155: ...3 9 Confidential Hinge ASSY L Fig 3 7 Hinge R Legal model only Fig 3 8 ...
Page 277: ...Confidential CHAPTER 4 ADJUSTING AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Page 293: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 300: ...5 5 Confidential Fig 5 1 ...
Page 325: ...5 30 Confidential Fig 5 14 ...
Page 327: ...5 32 Confidential Fig 5 15 ...
Page 346: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Page 348: ...6 1 Confidential 1 WIRING DIAGRAM Wiring diagram ...
Page 349: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 368: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 372: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...