3-88
Confidential
(6) Remove the three taptite cup S M3x8 SR screws and four taptite bind B M4x12 screws,
and remove the main frame L ASSY from the machine. Then pull out the low-voltage
power supply harness, the eject sensor harness and the main HVPS flat cable from the
main frame L ASSY.
Fig. 3-117
Taptite cup S M3x8 SR
Taptite bind B M4x12
Taptite cup S M3x8 SR
Taptite bind B M4x12
Main frame L ASSY
Low-voltage power
supply harness
Eject sensor harness
Main HVPS flat
cable
Taptite cup S M3x8 SR
Taptite bind B M4x12
Main frame L ASSY