2-59
Confidential
Error code BA00
This error does not usually occur during normal use. The possible causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
An unidentified error occurred.
Error code BB00
A white level not within the standard was scanned when function code 55 was executed.
Error code BC00
Although operation was retried due to error AC00 that occurred while scanning the fax, white
or black correction data for the second side CIS was not within the correct range.
Error code BD00
A black level not within the standard was scanned when function code 55 was executed.
---
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Scanner Error
-
Step
Cause
Remedy
1
First side CIS unit or second
side CIS unit failure
Replace the first side CIS unit or second side
CIS unit.
2
Main PCB failure
Replace the main PCB ASSY.
Scan Unable BC
See Troubleshooting and routine maintenance chapter in User's Guide.
Step
Cause
Remedy
1
Incorrect correction data for
second side CIS
Execute function code 55.
2
Second side CIS unit failure
Replace the second side CIS unit.
3
Main PCB failure
Replace the main PCB ASSY.
Scanner Error
-
Step
Cause
Remedy
1
First side CIS unit or second
side CIS unit failure
Replace the first side CIS unit or second side
CIS unit.
2
Main PCB failure
Replace the main PCB ASSY.
Summary of Contents for MFC-8510DN
Page 27: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 43: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Page 143: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Page 155: ...3 9 Confidential Hinge ASSY L Fig 3 7 Hinge R Legal model only Fig 3 8 ...
Page 277: ...Confidential CHAPTER 4 ADJUSTING AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Page 293: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 300: ...5 5 Confidential Fig 5 1 ...
Page 325: ...5 30 Confidential Fig 5 14 ...
Page 327: ...5 32 Confidential Fig 5 15 ...
Page 346: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Page 348: ...6 1 Confidential 1 WIRING DIAGRAM Wiring diagram ...
Page 349: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 368: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 372: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...