9. ELECTRIC MECHANISM
HE-800B
140
Error status #17 Upper shaft motor does not operate during sewing.
Probable causes
Check/ repair/ adjust
Parts to be replaced
1. Poor connector contact
Check that connector P31 (CUTTER) is inserted
into the main PCB, that connectors P1 (POWER),
P2 (SOL) and P3 (MAIN) are inserted into the
cutter
PCB, and that connector P5 (CUTTER) is
inserted into the power PCB.
2.
Malfunction of cutter solenoid
Disconnect connector P2 (SOL) from the cutter
PCB, and measure the resistances between pins
1 and 3 and pins 2 and 4 of the cord-side
connector.
OK if 6Ω to 8Ω between 1 and 3, and 13Ω to 15Ω
between 2 and 4
.
Cutter solenoid assembly
3.
Malfunction of cutter PCB
a. Turn off the power switch, disconnect
connector P2 (SOL) from the cutter PCB, and
then check the continuity between terminals
1 and 3 and terminals 2 and 4 of connector
P2 on the cutter PCB.
OK if ∞Ω
b.
Insert connector P2 (SOL) into the cutter
PCB, turn on the power switch and carry out
sewing, and measure the voltages between
terminals 1 and 3 and terminals 2 and 4 of
connector P2.
OK if voltage is output momentarily at the
sewing end.
Cutter PCB assembly
0780D
0781D
Summary of Contents for HE-800B
Page 7: ...v HE 800B Oil tank accessory 4732M 4731M 4730M ...
Page 75: ...6 ASSEMBLY HE 800B 66 D E 0688D 0690D ...
Page 126: ...9 ELECTRIC MECHANISM HE 800B 117 Power PCB Cutter PCB LCD panel PCB 0831D 0768D 0769D ...
Page 133: ...9 ELECTRIC MECHANISM HE 800B 124 0851D ...
Page 134: ...9 ELECTRIC MECHANISM HE 800B 125 0852D ...
Page 135: ...9 ELECTRIC MECHANISM HE 800B 126 0853D ...
Page 177: ...MEMO 168 HE 800B ...
Page 178: ...SERVICE MANUAL 2014 Brother Industries Ltd All Rights Reserved HE 800B I3061003D 2014 03 D 1 ...