Chapter 8 Dipswitch
BAS-6150
95
No
Description
OFF
ON
Initial value
1
—
-
-
OFF
2
—
-
-
OFF
3
—
-
-
OFF
4
—
-
-
OFF
5
Motor error detection
do
don't
OFF
6
7
OFF
8
DIP-SW C (Main print circuit board)
Combination of ON and OFF of DIP SW 6, 7 and 8, set correction quantity of the needle upper
stop position. Refer to the table below.
No
Correction quantity
6
7
8
OFF
OFF
OFF
Initial set value
ON
OFF
OFF
Delay by 1 slit
OFF
ON
OFF
Delay by 2 slits
ON
ON
OFF
Delay by 3 slits
OFF
OFF
ON
Initial set value
ON
OFF
ON
Gain by 1 slit
OFF
ON
ON
Gain by 2 slits
ON
ON
ON
Gain by 3 slits
Correction quantity of needle upper stop position