Chapter 2 Sewing flow
BAS-6150
34
2-2. Test (step) operation
Operation of the switch can be performed for each step. In the test operation mode, the machine,
center knife, and corner knife do not operate.
1.
Select program Nos. by pressing
∆∇
key.
2.
Press the forward switch
q
several times and the clamp and the binder go down.
3.
Test operation starts with pressing the start switch
e
while pressing the "RESET" key
w
.
TEST is displayed in the contents display window
r
and the mode becomes the test operation mode.
4.
Continuous operation starts by continuous press of the start switch
e
.
5.
One step operation is performed by pressing the forward switch
q
.
6.
Continuous operation is performed by continuous press of the forward switch
q
.
7.
One step backward is performed by pressing the backward switch
t
.
8.
Continuous backward operation is performed by continuous press of the backward switch
t
.
9.
Press the "RESET" key
w
when the test operation is not performed to stop the test operation
mode.
1464S
1457S
1460S
t
q
w
r
e
Summary of Contents for BAS-6150
Page 2: ......
Page 11: ...Chapter 1 Machine Preparation ...
Page 29: ...Chapter 2 Sewing flow ...
Page 41: ...Chapter 3 Settings ...
Page 55: ...Chapter 4 Oiling ...
Page 59: ...Chapter 5 Adjustment For raising the head refer to 3 How to raisethehead in Chapter4 Oiling ...
Page 70: ...Chapter 5 Adjustment BAS 6150 68 ...
Page 71: ...Chapter 6 Knife replacement ...
Page 77: ...Chapter 7 Environment setting ...
Page 85: ...Chapter 7 Environment setting BAS 6150 83 Standard stacker 4 steps 0 1 3 4 2 1530S ...
Page 95: ...Chapter 8 Dipswitch ...
Page 98: ...Chapter 8 Dipswitch BAS 6150 96 ...
Page 99: ...Chapter 9 Error code List ...
Page 103: ...Chapter 10 Troubleshooting ...