![Brooks ABM 100 User Manual Download Page 173](http://html1.mh-extra.com/html/brooks/abm-100/abm-100_user-manual_2818768173.webp)
Maintenance
Atmospheric Single-Arm Robot
Diagnostics for the Single-Arm Robot
User’s Manual
Brooks Automation
9-26
Revision 1
1.
Change distance to index to be within 1000 and 3000 range counts with
these hardware changes.
2.
Loosen the motor mounting bracket on the track assembly after shutting
off power.
3.
Pop the belt of the idler pulley that is on the track (This pulley does not
contain any teeth and it is situated between main idler pulley and the
boggie roller pulley)
4.
Slide belt a couple of notches.
5.
Snap the belt back on the idler pulley.
6.
Tighten motor mounting bracket.
7.
Return to Step 1
8.
Go to
Adjusting the Distance to Index on an ABM 400 Series with Track
on page 9-25
and repeat the Galil commands to determine if the distance
to
TP
is between 1000 and 3000 counts. If it is not, continue with the pro-
cedure until the TP is in the correct range.