994
Fabric OS Command Reference
53-1001764-01
switchShow
22
1211 8 59 0 ------ -- 16G No_Module FC
1212 8 60 0 ------ -- 16G No_Module FC
1213 8 61 0 ------ -- 16G No_Module FC
1214 8 62 8 ------ id 16G No_SigDet FC
1215 8 63 8 ------ id 16G No_SigDet FC
To display media type information (relevant output excerpts only):
•
The following example shows
switchshow
output for the ge0 and ge1 ports on a Brocade 7800.
The ge0 port is a copper port (default). The ge1 has an SFP installed (copper or optical):
[...]
ge0 cu 1G No_Sync FCIP Copper
ge1 id 1G No_Light FCIP
ge2 -- 1G No_Module FCIP
ge3 -- 1G No_Module FCIP
ge4 id 1G Online FCIP
ge5 -- 1G No_Module FCIP
[...]
•
This example shows
switchshow
output for a Brocade 5100. Port 31 has an SFP installed. Nothing
is installed on Port 32.
[...]
31 31 421f00 id N4 In_Sync FC Disabled
32 32 422000 -- N8 No_Module FC Disabled
[...]
•
The
sfpShow
output for the same switch displays the serial number for the SFP.
[...]
Port 31: id (sw) Vendor: BROCADE Serial No: UAF1081800000MK
Speed: 200,400,800_MB/s
Port 32: --
[...]
SEE ALSO
fabricName
,
portCfgLongDistance
,
switchDisable
,
switchEnable
,
switchName
Summary of Contents for Fabric OS v7.0.1
Page 1: ...53 1002447 01 15 December 2011 Fabric OS Command Reference Supporting Fabric OS v7 0 1 ...
Page 6: ...vi Fabric OS Command Reference 53 1002447 01 ...
Page 30: ...4 Fabric OS Command Reference 53 1002447 01 Using the command line interface 1 ...
Page 1132: ...1106 Fabric OS Command Reference 53 1002447 01 General Fabric OS commands and permissions A ...