74
Fabric OS Command Reference
53-1001764-01
bottleneckMon
22
Enabling or disabling bottleneck detection is a switch-wide operation. If Virtual Fabrics are enabled, the
configuration is applied per logical switch and affects all ports on the current logical switch. After the
(logical) switch-wide bottleneck detection parameters have been set, you can you can fine-tune the
configuration for specific ports.
A bottleneck is defined as a condition where the offered load at a given port exceeds the throughput at
the port. This command supports detection of two types of bottleneck conditions: congestion and latency.
•
A congestion bottleneck arises from link over-utilization. This happens when the offered load
exceeds throughput and throughput is at 100%. Frames attempt to egress at a faster rate than the
line rate allows. Link utilization is measured once every second at the port. When trunked ports are
monitored, link utilization is measured for the entire trunk. A congestion bottleneck is assumed if the
utilization during the measured second is 95% or more.
•
A latency bottleneck occurs when egress throughput at a port is lower than the offered load because
of latency in the return of credits from the other end of the link. This is not a permanent condition.
The offered load exceeds throughput and throughput is less than 100%. In this case, the load does
not exceed the physical capacity of the channel as such, but can occur because of an
underperforming device connected to the F_Port, or because of back pressure from other
congestion or latency bottlenecks on the E_Ports. Bottleneck detection can help identify these
devices and pinpoint the upstream bottlenecks caused by these devices inside the fabric.
When bottleneck detection is enabled on a switch and
-alert
is specified, the command triggers an
SNMP and a RASlog alert when the ports on the configured switch experience latency or congestion.
Another alert is sent after the condition resolves. For a given averaging time, each second is marked as
affected by latency and/or congestion or not. If the number of affected seconds crosses the configured
threshold, an alert is triggered for the port. You can configure a severity threshold for each type of
bottleneck and the time interval over which the bottlenecks are measured.
For example, setting a latency threshold of 0.8 and a time window of 30 seconds specifies that an alert
should be sent when 80% of the one-second samples over any period of 30 seconds were affected by
latency bottleneck conditions. The
-qtime
option can be used to throttle alerts by specifying the minimum
number of seconds between consecutive alerts. Thresholds are configured separately for each type of
bottleneck and statistical data are collected independently for each condition. The
-qtime
parameter
applies to both types of bottleneck detection; there can be one latency alert and one congestion alert in a
configured quiet time.
Bottleneck detection works both in non-Virtual Fabric mode and in Virtual Fabric Mode. If Virtual Fabrics
are enabled, bottleneck detection is configured per logical switch. If a port is removed from a logical
switch after bottleneck detection is enabled on the logical switch, the configuration is retained in that
logical switch. If the port is added again to the same logical switch, bottleneck detection is automatically
re-enabled for this port using the retained configuration. This feature allows you to configure more than
one logical switch to perform bottleneck detection on the same port, although only one logical switch
performs the operation on the port at any given time.
The
--show
option displays a history of the bottleneck severity for a specified port or for all ports. Each
line of output shows the percentage of one-second intervals affected by bottleneck conditions during the
time window shown on that line. When issued for all ports, the union of all port statistics is displayed in
addition to individual port statistics. The union value provides a good indicator for the overall bottleneck
severity on the switch. You can filter the output to display only latency or congestion bottleneck statistics.
When used without port operand the command displays the number of ports affected by bottleneck
conditions. A "bottlenecked" port in this output is defined as any port that was affected by a bottleneck for
one second or more in the corresponding interval.
When using the
--show
command, you may see a "no data for x seconds" or "no data" message
displayed at the end of a line of output. The "no data..." message in any interval means that there was no
data to analyze for the stated number of seconds or for the entire interval if the remark is simply "no
data." This typically means that there was no traffic on the link for the stated number of seconds. The
percentage of affected seconds displayed takes this into account. For example, if there was no traffic for
Summary of Contents for Fabric OS v7.0.1
Page 1: ...53 1002447 01 15 December 2011 Fabric OS Command Reference Supporting Fabric OS v7 0 1 ...
Page 6: ...vi Fabric OS Command Reference 53 1002447 01 ...
Page 30: ...4 Fabric OS Command Reference 53 1002447 01 Using the command line interface 1 ...
Page 1132: ...1106 Fabric OS Command Reference 53 1002447 01 General Fabric OS commands and permissions A ...