-7-
Gas Pressures (Inches WC)
Natural Propane (LP)
Inlet Minimum
5.0
11.0
Inlet Maximum
10.0
14.0
Manifold Pressure 1.6 to 3.5
6.4 to 10
Gas Specifications & Orifice Size
Fuel Max. Input
BTU/h
Min. Input
BTU/h
Orifice
Size
Nat.
43,500
28,500
#30 DMS
LP
40,500
30,500
#48 DMS
Natural Gas & LP Gas
HIGH ELEVATIONS
Input ratings are shown in BTU per hour and are certified without derating for elevations up to 4,500 feet (1,370
m) above sea level. For elevations above 2,000 feet (50.8 m) in USA, installations must be in accordance with the
current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction. In Canada, please consult provincial and/
or local authorities having jurisdiction for installations at elevations above 4,500 feet (1,370 m). Natural Gas and
Propane Installation Code, CSA B149.1 NOTE: If you live in a cold climate, seal all cracks around your appliance,
and wherever cold air could enter the room, with noncombustible material. It is especially important to insulate
the outside chase cavity between the studs and under the floor on which the appliance rests, if the floor is above
ground level. NOTE: Failure to follow these instructions will void the warranty.
Part Overview
Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping
damage and immediately inform your authorized dealer if any damage is found. Do not install any damaged,
incomplete, or substitute parts. Check your packing list to verify that all listed parts have been received.
AA BATTERIES
(4 PACK)
REMOTE
9V BATTERY
BOX
AAA BATTERIES
(3 PACK)
WARNING: Do not pack the open air spaces with insulation or other materials. This could cause high temperatures
and may present a fire hazard and serious injury, property damage or loss of life. Operation of improperly
installed and maintained venting system could result in serious injury, property damage or loss of life.
WARNING: This appliance must be vented to the outside. The venting system must NEVER be attached to
a chimney serving a separate solid fuel burning appliance. Each gas appliance must use a separate vent
system. Do not use common vent systems.
WARNING: Read all instructions completely and thoroughly before attempting installation. Failure to do so
could result in serious injury, property damage or loss of life. Operation of improperly installed and maintained
venting system could result in serious injury, property damage or loss of life.
Venting
APPROVED VENT SYSTEMS
DuraVent, ICC, BDM, and Olympia components.
VENTING REQUIREMENTS
Consult the local and national installation codes to assure adequate combustion and ventilation air is available.
Venting requirements apply to both natural gas and LP gas.
•
Flame height and appearance will vary depending upon venting configuration and the type of fuel used.
• Refer to the vent manufacturer’s installation manual for complete installation instructions. Vent installation
must conform with venting requirements and restrictions as outlined in this manual.
• Provide a means for visually checking the vent connection to the appliance after it is installed.
VENT SECTION CLEARANCES
NOTE: Wall thimble products that comply with the required 1 in (25 mm) clearance to combustibles must be
installed for all horizontal vent runs that pass through interior or exterior walls. These wall thimble products may be
insulated using unfaced insulation products listed as noncombustible per ASTM E 136.