-20-
Replacement Parts And Service
OVER FIRING OF BURNER
Never "over fire" adjusting gas pressure or drilling out the orifice to increase Btu/hr above nameplate specifications.
Over firing can cause permanent damage to firebox and deterioration of parts and void warranty.
MAINTAINING CORRECT PILOT-FLAME
The pilot flame must be checked during initial installation and annually by a qualified technician. This appliance
uses flame rectification technology. If the pilot flame is turned down too low, the flame sensor may not detect the
pilot flame and the pilot may not stay lit. Do not turn down the pilot flame. The flame sensor rod may be coated
with debris after a few months of use. It is important to clean the flame sensor rod using emery cloth if flame
rectification problems are encountered after use for a few months. Environmental factors beyond the control of
Breckwell can cause flame rectification concerns.
Part No.
Description
Qty.
610963 Rear Tray Assembly
1
610964 Front Tray Assembly
1
28909
Pass Through Cover
2
80775
High Temp Light Assembly
2
80766
G9 Base Bulb
2
28832
Burner Plate
1
88307
Light Gasket
2
88309
Pass Through Gasket
4
610708 Glass Frame Assembly
1
29197
Control Cover Tray
1
80709
Blower (Optional)
2
28815
Valve Mounting Bracket
1
88323
Shielding Gasket
1
81289
Sit Ignition Control Module (IFC)
1
80850
IFC On/Off Switch Harness, 8”
1
80649
Ground Wire
1
80773
IFC Fan/Light Harness, 11.50”
1
C42373 Rocker Switch
1
610686 Junction Box Assembly
1
610563 Burner Assembly
1
81297
Gas Pilot
1
80762
Sit Transmitter (Remote) (Sit #0.584.042 or .040)
1
80763
IFC Wire Harness No CPI SW SIT 0.584.924