background image

 

BRAVE 

– user guide 

 

47 

5.8  Default settting and erasing 

Parametr  Value 

Description 

Default 

8# 

Default 

execute 

This setting doesnt change parametres 

1

 and 

2

 (numbers saved in memories) 

 

Parametr  Value 

Description 

Default 

81 

 

Erase all numbers in group 1  

(Day mode)  

 

82 

 

Erase all numbers in group 2  

(Night mode)  

 

83 

 

Default settings for parametres  3x only 

3 only.. 

84 

 

Default settings for parametres  4x only  

4 only.. 

85 

 

Default settings for parametres  5x only  

    5 only.. 

86 

 

Default settings for parametres  6x only  

6 only.. 

87 

 

Default settings for parametres  7x only  

    7 only.. 

80 

 

Default settings for parametres  0x only  

0 only.. 

Parametres 81 and 82 makes erasing of all numbers saved in button memories. 
Parametres 83 

– 87,80 makes default settings for parametres starts 3,4,5,6,7,0 

only. Default settings values are mentioned at every parametr in right  - column  
"Default". 

CAUTION !!!

 the erasing is unreturnable !!! it is neccessary programm again 

 

5.9  Programming termination 

Parametr  Value 

Description 

Default 

 

E N D of programming 

 

After 

9

 dial in programming tone the door intercom hangs up. 

Summary of Contents for Smyle - C

Page 1: ...Brave Smyle C Brave Smyle LC Brave Smyle C C User guide Version 2 6 Brave Door Intercom ...

Page 2: ......

Page 3: ...tion only IP 44 casing protection LED cards lighting Integrated analog color camera C C LC C 1 2 relay with 8 different operational modes possibility to use electrical lock PSU for feeding the unit C elektronical loudness settings without neccessity open the unit adjustable tones detection for REDIAL or Hanging Up integrated RTC realtimeclock circuit automatical DAY NIGHT switching C programming b...

Page 4: ... 2 2 1 Code relay COSW 16 2 3 CAMERA C VERSION ONLY 18 2 4 ACCSSESORIES 19 2 4 1 Weather hood 19 2 4 2 TimeRelay 19 2 4 3 DistyBox 19 2 4 4 Power supply 12V 20 2 4 5 Programming cable USB 20 2 4 6 BlackBox 20 3 DOOR INTERCOM SERVICE 21 3 1 SIGNALLING OVERVIEW 21 3 2 VISITOR AT THE DOOR 22 3 3 PERSON INSIDE BUILDING 24 3 3 1 Outgoing call 24 3 3 2 Incoming call 25 3 4 ACOUSTIC PATH SETTING 25 4 PAR...

Page 5: ... HANDSFREE PARAMETRES SETTING 42 5 7 TIME PROGRAMM AUTOMATIC DAY NIGHT SWITCHING C 45 5 8 DEFAULT SETTTING AND ERASING 47 5 9 PROGRAMMING TERMINATION 47 5 10 PARAMETRES OVERVIEW 48 6 TECHNICAL PARAMETRES 52 6 1 ELEKTRICAL PARAMETRES 52 6 2 MECHANICAL DIMENSIONS 52 7 TABLE FOR EASY PROGRAMMING 53 ...

Page 6: ...ame push button Possible switched on mode Baby Call Possible switched on suppress receive DTMF by microphone Possible switched on accoustic tick to the conversation for speech recognition Possible switched on accoustic signalization of close the relay Adjustable number of rings before pick up an incoming call Adjustable parameters of tone dial length of Flash and Pause Adjustable parametres of aco...

Page 7: ...d party This stage is not signalled at analog line It just stop ringing tone and call starts It is difficult identify just this moment El lock code function for relay closing by dial digits combination from intercom buttons Code relay between Doorphone Brave and the electric lock can be connected code relay COSW CodeSwitch which is located at the lock and lock activates only when is the same the s...

Page 8: ...except particularly marked Model C is version equiped by full colour analog camera Model C comfort has special features marked by C Model M modular has marked M in mechanical Smyle solution is not produced And it is mentioned in programming tables only which are same for all models 1 4 Models of Brave door intercom SMYLE models of Brave LC C includes appropriate mother board with all connectable e...

Page 9: ...1 5 PCB Schematics All functional and connectional elements are marked by red rounded number at bellow picture Explanation follow on next page Pict 1 Brave Smyle mother board 1 3 7 11 version C only relay 2 version C only ...

Page 10: ...t consumption on its extensions during start Siemens 5 Camera lighting up switch ON OFF lighting of space before camera via infra LED 6 Cards lighting switch ON OFF Leds backlighting for cards beside button 7 Activate permanent camera operation In default camera is active only when door intercom is active 8 Allows connect 75ohm to camera output impedance 8 Analog telephone line not depends on pola...

Page 11: ...y It is useful mainly at installations where power supply is already installed and it is used for sliding doors RFID etc The heating has control element to restrict power The remaining components are designed for voltage up 24V DC It not depends on polarity ...

Page 12: ...BRAVE user guide 12 2 Installation 2 1 Assembly 2 1 1 Assembly of Brave Smyle front panel ...

Page 13: ...BRAVE user guide 13 2 1 2 Assembly of cards backlighting 2 1 3 Wall mounting of Brave Smyle Make the mounting by attached pack with screws and plug drill 5mm ...

Page 14: ...ng of cards backlighting after wall mounting 2 1 5 Cards exchange name cards Every button has own card label holded by plastic flag via picture You can print out paper labels from special Excel file downloadable on www alphatech cz or ...

Page 15: ...ure 1 5 and camera is either activated automatically when intercom is active or is permanently ON DIP 7 Camera lighting up by infra LED is either active with camera DIP 5 or you can permanently switch OFF Due DIP 8 you can paralelly connect to video output impedance 75ohm 12V power supply 12 on Pict 1 must be connected for mother board heating cards backlighting camera powering inludes infra LEDs ...

Page 16: ... DAY NIGHT mode m 8 C version only RTC circuit External power supply required DIP 3 and 4 C version only Further is neccessary use contactor Brave Smyle must not activate 230V 2 2 1 Code relay COSW For the first switch is available function code relay COSW CodeSwitch It serves primarily to secure transmission of information by switching the electric lock When using this function is not possible co...

Page 17: ...BRAVE user guide 17 Pict 2 Examples of relay connection ...

Page 18: ... parametres videonorm PAL CCIR sensor CMOS 1 3 picture area 5 78x4 19mm resolution 628x582pixel 380 rows video output 1V p p 75 ohm automatic profit control 18dB minimal lighting 3LUX automatic lens shutter 1 60 1 15000sekund camera view 50st zoom manually ...

Page 19: ...es www alphatech cz 2 4 3 DistyBox This optional modul is plastic box allows you to connect analog unit phone intercom into wireless system DECT GAP for example Siemens line GigaSet TopCom line Butler etc DistyBox is suitable for intercom connection when are cables not available You just registrate intercom as handset to DECT base station All features of intercom are kept Important DECT base stati...

Page 20: ...ly More info about electrical locks and power supply on www alphatech cz 2 4 5 Programming cable USB USB cable is not part of packaging It must be ordered individualy USB drivers are downloadable on www alphatech cz 2 4 6 BlackBox BlackBox is DTMF modem useful for remote programming from PC Via BraveSet programm you can remotely setup all parametres of Brave Smyle intercom 3 ...

Page 21: ...p OFF HOOK type 2 800 1067 1200 1333 Line hang up ON HOOK type2 1333 1200 1067 800 Command confirmation by phone 800 Alerting knocking into call Call ending alert 1333 Relay activation signal Modulovaný Programming enter by phone 980 1067 1180 Programming by phone Modulovaný Parametr confirmation 800 Programming enter by PC 980 1067 1180 Line connection Reset 1850 1067 1850 Error generally all inc...

Page 22: ...by parametres 45 46 In version C you can switch DAY NIGHT mode automatically Selection of dialled number saved under the button is control by time up table parametry 00 06 2 groups numbers mode first button push always dial number setup by parametr 1 When the same button is pushed or 10seconds after dial busy tone is detected or setup number of rings is out parametr 56 the door intercom dial numbe...

Page 23: ...code 2digits code is default You can shorter it by using on first digit of code during programming 351 352 361 362 Mode m 5 parametr 3125 Action Note Parametr Relay Evaluation of correct external code from buttons 3211 3215 According settings DAY NIGHT 3311 3315 3411 3415 3221 3225 According settings DAY NIGHT 3321 3325 3421 3425 321 According settings DAY NIGHT 331 341 322 According settings DAY ...

Page 24: ... person in telephone connection with Brave intercom for example Mr Scott 3 3 1 Outgoing call Outgoing call is a call from door intercom generated by visitor After door intercom dial is ringing a phone inside the building When you pick up the phone you can talk to visitor By code dialling you can activate the relay parametr 35 when relay is setup in mode m 1 or m 5 You also can switch operation mod...

Page 25: ...iet environment parameters 71 72 73 are set to 7 2 environment where is a strong ambient noise at the communicator and quiet environment at the phone Here is both necessary to reduce the microphone gain parameter 72 1 3 and also change the ratio of the parameters 71 73 way 73 enlarge the the parameter parameter 73 11 15 and 71 parameter smaller value 71 2 4 3 environment where is a strong ambient ...

Page 26: ...a capture 3 1 page 21 4 1 2 Parametres programming Stand by stage of programming is announced by programming tone into which door intercom always returns after time out 5sec whenever you started to programm There are two kind of parametres you can programm First are parametres with fix length Most of parametres are those The parametr is saved immediatelly after inserting mandatory length you hear ...

Page 27: ...n programm BraveSet is running The door intercom stays pasive until moment of USB cable disconnection When you loose connection please disconnect USB cable from door intercom and connect it again door intercom picks up Correct connection PC with BraveSet programm is indicated by reading firmware version from door intercom visible in bar as same as reading the time shown in left top corner When you...

Page 28: ...Numbers saved in parametr 1 are numbers of first group or numbers of DAY mode Default settings doesnt erase as same as changed those saved numbers Parametr Value Description Default 2 tt nn číslo nn pod tlačítkem tt tt button number memory always has 2 digits 01 99 nn phone number up 24 digits which you desire to save For saving further characters use assignments mentioned in table Numbers saved i...

Page 29: ...intercom picks up and open by hanging up m 3 closed for time of line OFF HOOK and more for time t1 t4 after hang up lighting closed when door intercom picks up and stays closed for time t1 t4 after door intercom hangs up for this time line is busy at version C and C is after switching DIP 3 4 and settings parametr 64 for time t1 t4 line hanged up m 4 mode button closed when any button is pushed an...

Page 30: ...t1 t4 of relay r Parametr Value Description Default 32 rp hh In mode DAY NIGHT password hh for relay r in order p 1 5 for 1 pulse and p for 2 pulses 00 999999 33 rp hh In mode DAY password hh for relay r in order p 1 5 for 1 pulse and p for 2 pulses 00 999999 34 rp hh In mode NIGHT password hh for relay r in order p 1 5 for 1 pulse and p for 2 pulses 00 999999 r relay number 1 2 p order 1 5 for 1 ...

Page 31: ... command for relay activation as same as door intercom hang up parametr 43 aa bb 1 command has always 2 digits but when you want control relay by 1 digit only from keypad of phone then you have possibility to programm a where a is one number only which activate the relay star represents empty character and must be on first digit position Example 1 relay activated by internal code 48 dial 35148 2 r...

Page 32: ...ault 38 r p Control relay r during incoming call 0 1 11 21 r relay number 1 2 p parametr which says permitted p 1 or forbidden p 0 control relay during incoming call To prohibit control of relay during incoming call has a sense for example by relay2 in mode 1 by which you control sliding gate opening where door intercom open the gate and after car passing the gate is closed Then control by phone c...

Page 33: ...namely for 1 pulse Parametr Value Description Default 3 2 abcd activation code 1 pulse from phone 0000 1111 0000 abcd Brave sends a serial code for the code relay COSW after evaluation code from telephone DTMF namely for 1 pulse Parametr Value Description Default 3 3 abcd activation code 2 pulses from buttons 0000 1111 0000 abcd Brave sends a serial code for the code relay COSW after evaluation co...

Page 34: ... 9 155 266 g command order 1 2 they are two to be possibility hang up door intercom when each relay is used bb command to hang up door intercom by phone 2 digits 1 It is profitable setup the same command to hang up door intercom as same as activate relay parametr 35 36 aa bb or aa cc 1 command has always 2 digits but if you want use 1 digit then you have possibility insert a where a is just one nu...

Page 35: ...ion Note Switching into DAY or NIGHT mode stays setup even after power line disconnection from door intercom Parametr Value Description Default 47 e Door intercom dial mode 0 1 1 e dial numbers mode e 0 dial numbers from first and second group e 1 numbers are dialled up DAY NIGHT mode in door intercom CAUTION setting of this parametr has a big influence to numbers dialling Parametr Value Descripti...

Page 36: ... time for which door intercom is OFF HOOK This time you can prolong by dial character during a call by phone or parametr 42 Setting of time is up table Parametr Value Description Default 53 w Time between button push 1 9 2 w maximal time sec between button push range 1 9 normal buttons relay activation when time between push of 2 following buttons is longer than time w then code is evaluated incor...

Page 37: ...up 04 99 12 h after dial termination calculate number of CRT control ring tones When number is higher than hh then hang up range 04 99 Dial is repeated in case of 2 groups mode Parametr Value Description Default 500 x Middle frequency of tones detector 1 0 3 375 475Hz 501 y Number of busy tones 2 0 4 502 z Time of permanent tone duration 1 5 3 3s x middle frequency of tones detector is suitable wh...

Page 38: ...duration time ms range 1 6 tj 100 600ms p Time of pause duration is calculated inserted number x 100 400 pause duration time ms range 1 0 tj 500 1400ms time p is also time of pause between numbers at pulse dialling Parametr Value Description Default 507 uu Level of sending tone DTMF dial in dBm 04 16 10 uu level of sending tone DTMF dial into line range is 4 to 16dBm You insert desired level uu 04...

Page 39: ... Value Description Default 63 u Acoustic signalling knocking to call 0 1 0 In default it is switch off By activation of this feature you can identify at PBX calling from door intercom just up knocking into call Possible values are u 0 knocking to call is off u 1 knocking to call is on Parametr Value Description Default 64 w Powering from external power supply 12V DIP 3 4 0 1 0 In version C only or...

Page 40: ...without ringing to person inside building To increase security you can activate suppression of DTMF reception from microphone i 1 and due this protect entrance of persons who provided record of DTMF code for door opening Parametr Value Description Default 67 b BabyCall call without neccessity programm phone number 0 1 0 In default is switch off b 0 By activation this feature b 1 is cancelled acous...

Page 41: ... mode after line connection and after 3sec the door intercom makes initialization It delays line picks up after line voltage connection activation status PBX restart When this feature is not efficient and PBX still evaluate the line into failure mode then you have to use external power supply put DIP switch 3 and 4 to position on possible at version C C only It is the same like using Best Box opti...

Page 42: ...ing When you dont press any digit within 5sec then setup value is saved and you hear confirmation tone CAUTION We dont recommend factory setting if neccessary Parametr Value Description Default 74 c Soft pass of switching 0 1 1 In default this feature is off c 0 It is going about character of on line operation semiduplex switching In case where character of depresser is too steep you can make it s...

Page 43: ...ironment we recommend higher value with combination of parametrs 71 75 77 Parametr Value Description Default 77 s Fast switching voice automatic 1 4 4 is slowest 2 At parametres 75 76 is descriped principal of acoustic shock supression Speed of circuit switching between incoming and outgoing sound is setup by parametr 77 Parametr Value Description Default 78 l VoltAmper VA charakteristic of line c...

Page 44: ...BX can compensate losses on wiring In default the feature is off k 0 You can setup in two levels depending on line current of PBX short circuit current I0 PBX current I0 k dial Feature is off 0 20mA 50mA 1 45mA 75mA 2 Parametr Value Description Default 70 uu Transmission signalling level in dBm 04 16 10 uu transmission signalling level to the line range 4 to 16dBm You insert desired level uu 04 is...

Page 45: ... have to setup the time By dial a 0 you deactivate automatical switching Parametr Value Description Default 081 hhnn Time settings hh hours nn minutes 082 ddmmyyw Date settings dd day mm month yy year w weekday 083 wait 1 min for seconds zeroing Internal clocks parametres setting After setting by command 083 zeroing seconds setting any through this agreed clocks exactly up seconds w weekday 0 Sund...

Page 46: ... nn starts day and hours kk and minutes jj starts night 00000000 07 overwrite copyright setting from sunday 00 into whole week By parametres 00 06 are setting times of automatic switching DAY NIGHT for every day in week The parametr 07 is designed for copying when setting is the same for whole week Then you setup switching times for parametr 00 sunday and then by parametr 07 you copy this setting ...

Page 47: ...rametres 5x only 5 only 86 Default settings for parametres 6x only 6 only 87 Default settings for parametres 7x only 7 only 80 Default settings for parametres 0x only 0 only Parametres 81 and 82 makes erasing of all numbers saved in button memories Parametres 83 87 80 makes default settings for parametres starts 3 4 5 6 7 0 only Default settings values are mentioned at every parametr in right colu...

Page 48: ... 0 9 155 266 36 r cc command aa from phone for closing relay r 2 pulses 00 99 0 9 150 260 37 r ss time ss sec relay closing r for time t1 t4 01 99 105 205 38 r p Relay control r during incoming call 0 1 11 21 39 xx time xx sec between relay closing 1 and 2 in mode m 5 doba t3 01 99 10 30 r zz time zz sec between pulses during closing for 2 pulses of relay r doba t2 t5 01 99 105 205 3 0 p p 1 enabl...

Page 49: ... 04 99 12 500 x Middle frequency of tone detector 1 0 3 375 475Hz 501 y Number of busy tones 2 0 4 502 z Duration time of permanent tone 1 5 3 3s 503 tt Duration time of tone DTMF of tone dial 04 16 10 100ms 504 mm Time of space between each DTMF tones 04 16 10 100ms 505 f Flash duration time 1 6 1 100ms 506 p Pause duration time space between numbers 1 0 4 800ms 507 uu Transmitting level of DTMF ...

Page 50: ...s on line current 0 1 2 1 70 uu Transmission signalling level in dBm 04 16 10 09 a ON OFF automatic switching DAY NIGHT mode and time settings control 0 1 0 081 hhnn Time settings hh hours nn minutes 082 ddmmyy Date settings dd day mm month yy year 083 Wait for 1 min for seconds zeroing 00 hhnnkkjj sunday time setting hours hh and minutes nn starts day and hours kk and minutes jj starts night 0000...

Page 51: ...overwrite copyright setting from sunday 00 into whole week 8 default execute 81 Erase all numbers in group 1 DAY mode 82 Erase all numbers in group 2 NIGHT mode 83 Default setting for parametres 3x only 3 only 84 Default setting for parametres 4x only 4 only 85 Default setting for parametres 5x only 5 only 86 Default setting for parametres 6x only 6 only 87 Default setting for parametres 7x only 7...

Page 52: ...dial level 6 and 8 dB 1 20 60 mA Sensitivity of tone dial min 40 dB 20 60 mA Sensitivity of tones detector min 30 dB 20 60 mA Powering of backlight relays and heating 12Vss 2V 10 12Vst 2V Max consumption of backlight and heating 250mA 12Vss Max voltage of relay contact 48V when I 1A Max current of relay contact 1 5A when U 30 V Operation temperature 20 to 60 st IP rate IP44 Weight max 350g Camera ...

Page 53: ... Day 1gr 107 24 Number under button 8 Day 1gr 108 24 Number under button 9 Day 1gr 109 24 Number under button 10 Day 1gr 110 24 Number under button 11 Day 1gr 111 24 Number under button 12 Day 1gr 112 24 1 Number under button Night 2gr 201 24 2 Number under button Night 2gr 202 24 3 Number under button Night 2gr 203 24 4 Number under button Night 2gr 204 24 5 Number under button Night 2gr 205 24 6...

Page 54: ...3 6 Password relay 1 1 pulse Day 3314 6 Password relay 1 1 pulse Day 3315 6 Password relay 1 2 pulses Day 331 6 password relay 2 1 pulse Day 3321 6 password relay 2 1 pulse Day 3322 6 password relay 2 1 pulse Day 3323 6 password relay 2 1 pulse Day 3324 6 password relay 2 1 pulse Day 3325 6 password relay 2 2 pulses Day 332 6 Password relay 1 1 pulse Night 3411 6 Password relay 1 1 pulse Night 341...

Page 55: ...COSW sw 1 0 1 3 0 1 code for activation 1 imp btn 0000 1111 3 1 4 code for activation 1 imp phn 0000 1111 3 2 4 code for activation 2 imp btn 0000 1111 3 3 4 code for activation 2 imp phn 0000 1111 3 4 4 code for activation other mode 0000 1111 3 5 4 Dial type tone pulse 0 1 41 1 Call prolongation character 42 1 Brave hanging up by phone 1 431 2 Brave hanging up by phone 2 432 2 Service password 4...

Page 56: ...63 1 External power supply 12V 0 1 64 1 Acustic signalling of relay activation 0 1 65 1 Depression of DTMF reception from microphone 0 1 66 1 BabyCall 0 1 67 1 Mute at the lock activated 0 1 68 1 Number of buttons on panel Up model 6 1 Delayed start Siemens 6 1 Reception loudness TRH 01 16 71 2 Transmission loudness MIC 01 16 72 2 Speaker loudness SPK 01 16 73 2 Soft pass of switching 0 1 74 1 Dep...

Page 57: ...57 Time setting hhnn 081 4 Date setting weekday w ddmmyyw 082 7 sunday hhnnkkjj 00 8 Monday hhnnkkjj 01 8 Tuesday hhnnkkjj 02 8 Wednesday hhnnkkjj 03 8 thursday hhnnkkjj 04 8 friday hhnnkkjj 05 8 saturday hhnnkkjj 06 8 ...

Page 58: ... JR 2011 13 verze 2 6 X 13 Producer Distributor Sales date ...

Reviews: