BRAVE
– user guide
10
1. Camera lighting - infra LED. It lights up space before camera when is active.
It is possible switch off (via. item 7)
– version for camera only /C
2. Connector to PC connection via USB cable
3. Analog colour camera
– version with camera /C only
4. Speaker connection
5. Microphone connection (caution on polarity)
6. DIP switch in all models:
1 = Service, usage
– when programming
password is forgotton. Incoming call is
going directly to programming mode
where you can set new password.
2 = Heating
– switch ON integrated heating of mother board to increase resistance
against condensation water during changes of temperature
7. DIP switch position in versions
(C)
and
/C
:
3 = external power supply
4 = external power supply
– switching 3 and 4 simultaneously. The powering is
used from screw 12V (11) due following reasons:
- using relay mode 7 or 8
– tpermanent switching ON/OFF is possible only
with external power supply. Dont forget setup parametr 64.
- Connection of door intercom to certain type of PBX which has problems
with current consumption on its extensions during start (Siemens).
5 = Camera lighting up (switch ON/OFF lighting of space before camera via infra
LED)
6 = Cards lighting (switch ON/OFF Leds backlighting for cards beside button)
7 = Activate permanent camera operation. In default camera is active only when
door intercom is active.
8 = Allows connect 75ohm to camera output - impedance
8. Analog telephone line (not depends on polarity)
9. Grounding
– connection to ground of static electricity protection – protects
electronic of door intercom as same as PBX
10. Relays are galvanically isolated - max. 48V, max. 1,5A
model
(C)
has 2 relays
model
(LC)
has 1 relay only
on switch 1 is available relay function code (COSW - CodeSwitch) (see
page16)
11.
Camera output - PAL video 1V / 75ohm. For distance longer than 25m we
recommend coax cable. For other installation UTP cable is also available.
/C
model only
12. 12V power supply: - relays control
- mother board heating
- cards backlighting
- camera powering and infra LED camera lighting up
- external powering of unit (DIP 3 and 4)
The power supply might be AC as same as DC, not depends on polarity,
max consumption 250mA from 12V.
The power supply might be used also for electrical lock powering. Then we
recommend power supply 12V/1A.
Summary of Contents for Smyle - C
Page 1: ...Brave Smyle C Brave Smyle LC Brave Smyle C C User guide Version 2 6 Brave Door Intercom ...
Page 2: ......
Page 12: ...BRAVE user guide 12 2 Installation 2 1 Assembly 2 1 1 Assembly of Brave Smyle front panel ...
Page 17: ...BRAVE user guide 17 Pict 2 Examples of relay connection ...
Page 58: ... JR 2011 13 verze 2 6 X 13 Producer Distributor Sales date ...