BRAVE
– user guide
37
Parametr Value
Description
Default
54
z
Hanging up time during REDIAL (1-5)
2
z
– time [sec] for which door intercom hangs up before pick up for REDIAL
(button push during call, busy tone detection) [range 1-5]
Parametr Value
Description
Default
55
z
Time before start dialling (1-5)
1
z
– time [sec] after door intercom picks up and before start dialling [range 1-5].
This time is different for every PBX but usually all PBXs accepts dial within 2
seconds after line is picked up.
Parametr Value
Description
Default
56
hh
Number of rings before hang up (04-99)
12
h
– after dial termination calculate number of CRT (control ring tones). When
number is higher than
hh
then hang up [range 04-99]. Dial is repeated in
case of 2 groups mode.
Parametr Value
Description
Default
500
x
Middle frequency of tones detector (1-0)
3
(375-475Hz)
501
y
Number of busy tones (2-0)
4
502
z
Time of permanent tone duration (1-5)
3 (3s)
x
–
middle frequency of tones detector
– is suitable when PBX signalling is
unusual:
y
–
minimal number of busy tones neccessary for
detection [2-0], where 0 means 10 busy tones
z
–
minimal time of permanent tone duration (for dial
tone detection on PBX) [1-5 sec]
Parametr Value
Description
Default
frequency
[Hz]
x - dial
275-375
1
325-425
2
375-475
3
425-525
4
475-575
5
525-625
6
575-675
7
625-725
8
675-775
9
725-825
0
Summary of Contents for Smyle - C
Page 1: ...Brave Smyle C Brave Smyle LC Brave Smyle C C User guide Version 2 6 Brave Door Intercom ...
Page 2: ......
Page 12: ...BRAVE user guide 12 2 Installation 2 1 Assembly 2 1 1 Assembly of Brave Smyle front panel ...
Page 17: ...BRAVE user guide 17 Pict 2 Examples of relay connection ...
Page 58: ... JR 2011 13 verze 2 6 X 13 Producer Distributor Sales date ...