Depression of DTMF reception from
microphone (0/1)
0
67
b
BabyCall
– call without neccessity to insert
phone number (0/1)
0
68
b
Mute at the lock activated (0/1)
0
6*
t
Delay start for PBX´s with extension test
(Siemens) (0/1)
0
71
gg
Reception loudness 01-16 (16 is highest)
(SPK)
07
72
ff
Transmission loudness 01-16 (16 is highest)
(MIC)
07
73
rr
Speaker loudness 01-16 (16 is highest)
(TRH)
07
74
c
Soft pass of switching (0/1)
1
75
n
Depression of background sound (0/1)
1
76
b
Level of microphone start 1-4 (4 is highest)
2
77
s
Fast switching voice automatic 1-4 (4 is
slowest)
2
78
l
VoltAmper (VA) charakteristic of line
connection (0/1)
1
79
k
Compemsation of wires losses depends on
line current (0/1/2)
1
70
uu
Transmission signalling level in [-dBm] (04-
16)
10
09
a
ON/ OFF automatic switching DAY/NIGHT
mode and time settings control (0/1/#)
0
081
hhnn
Time settings hh-hours, nn-minutes
-
082
ddmmyy
Date settings dd-day,mm-month,yy-year
-
083
#
Wait for 1 min for seconds zeroing
-
00
hhnnkkjj
sunday
- time setting hours
hh
and minutes
nn
starts
day
and hours
kk
and minutes
jj
starts
night
00000000
01
hhnnkkjj
monday
- time setting hours
hh
and minutes
nn
starts
day
and hours
kk
and minutes
jj
starts
night
00000000
02
hhnnkkjj
tuesday
- time setting hours
hh
and minutes
nn
starts
day
and hours
kk
and minutes
jj
starts
night
00000000
03
hhnnkkjj
wednesday
- time setting hours
hh
and
minutes
nn
starts
day
and hours
kk
and
minutes
jj
starts
night
00000000
04
hhnnkkjj
thursday
- time setting hours
hh
and
minutes
nn
starts
day
and hours
kk
and
minutes
jj
starts
night
00000000
Summary of Contents for Smyle - C
Page 1: ...Brave Smyle C Brave Smyle LC Brave Smyle C C User guide Version 2 6 Brave Door Intercom ...
Page 2: ......
Page 12: ...BRAVE user guide 12 2 Installation 2 1 Assembly 2 1 1 Assembly of Brave Smyle front panel ...
Page 17: ...BRAVE user guide 17 Pict 2 Examples of relay connection ...
Page 58: ... JR 2011 13 verze 2 6 X 13 Producer Distributor Sales date ...