BRAVE
– user guide
40
Parametr Value
description
Default
65
z
Acustic signalling of relay activation (0/1)
0
In default the activation is off
z=0
. Usually you can use this fetaure for DC power
supply 12
V. Then when el.lock is released you dont hear „buzzing“ so visitor
doesnt know that el.lock is released. When you activate this feature
z=1
then
during relay activation you hear special sounds simulating relay activation.
Note.1
This feature is available for relay mode
m=1
,
m=5
only.
Note.2
For relay activation with 2 pulses the acoustic signalling sounds during
whole time of sequence. (even in space between pulses)
Parametr Value
Description
Default
66
i
Suppression of DTMF reception from
microphone (0/1)
0
In default the suppression of DTMF reception from MIC is off
i=0
. Due this you
can activate relay by personal dialler without ringing to person inside building. To
increase security you can activate suppression of DTMF reception from
microphone
i=1
and due this protect entrance of persons who provided record of
DTMF code for door opening.
Parametr Value
Description
Default
67
b
BabyCall
– call without neccessity programm
phone number (0/1)
0
In default is switch off
b=0
. By activation this feature
b=1
is cancelled acoustic
signalling of empty memory. After pushing of button with empty memory you get
just beep (confirmation) and call is established as normal dialled number
Caution:
first 10sec of call is not active tone detector (it waits on reaction of PBX
and number dialling by PBX)
Default is off m = 0 By enabling the m = 1 mutes the acoustic path at close relay
(1 or 2) in "electric lock" (modes 1 and 5). This feature is there because if you
often use code lock function or exit button, so the switch-on time to hear the tone
exchange. For some customers, this can be distracting.
Parameter
Value Meaning
Basic
68
b
Mute at the lock activated (0/1)
0
Summary of Contents for Smyle - C
Page 1: ...Brave Smyle C Brave Smyle LC Brave Smyle C C User guide Version 2 6 Brave Door Intercom ...
Page 2: ......
Page 12: ...BRAVE user guide 12 2 Installation 2 1 Assembly 2 1 1 Assembly of Brave Smyle front panel ...
Page 17: ...BRAVE user guide 17 Pict 2 Examples of relay connection ...
Page 58: ... JR 2011 13 verze 2 6 X 13 Producer Distributor Sales date ...