m=7
permanent closing
/ opening
– usable at versions
/C
and
(C
) only, if
switching (DIP 3,4)+par.64. By command for pulse 1 is closed and for
pulses2 is opened. This stage stays in door intercom even after power/line
disconnection. This mode you can use for potting, glasshouse opening,
heating activation etc..
m=8 activated
up DAY/NIGHT mode settings
- usable at versions
/C
and
(C
)
only, if switching (DIP 3,4)+par.64. Version
/C
allows copying manual
DAY/NIGHT switching only. Version
(C)
allows copying setting from week
table switching time (when is activated -
parametr 084
) and then you can
use for example for heating control etc…
Parametr Value
Description
Default
31
r* tt
button tt start relay closing r in mode m=6
(01-99)
01
r
– relay number [1-2]
tt
– button number (memory), always has 2 digits [01-99]
This parametr is for relay mode m=6 only. Value of tt designate from which
button start closing for time t1/t4 of relay r.
Parametr Value
Description
Default
32
rp hh...
In mode
DAY + NIGHT
password
hh...
for
relay
r,
in order p=1-5, for 1 pulse
and p=* for 2 pulses (00-999999)
-
33
rp hh...
In mode
DAY
password
hh...
for relay
r,
in
order p=1-5, for 1 pulse and p=* for 2
pulses (00-999999)
-
34
rp hh...
In mode
NIGHT
password
hh...
for relay
r,
in order p=1-5, for 1 pulse and p=* for 2
pulses (00-999999)
-
r
– relay number [1-2]
p
– order [1 - 5] for 1 pulse. 5 passswords (external codes) from door
intercom buttons (external code of codelock)
p
– order = *, then you can insert just one code (external code) for closing
by 2 pulses
hh...
– password (external code) for relay closing from buttons [2 to 6 digits].
Tlačítka 1 - 10 are programmable as numbers 1-0.
Totally 3 x 12 passwords. Controlled by settings DAY/NIGHT.
Combination is inserting by door intercom buttons
.
Relay closing is influenced
by setup relay
mode
and switching
DAY/NIGHT.
When is setup mode
2 groups
of numbers
the door intercom is permanently in mode
DAY
.
You have to keep certain rules for password dialling:
First button of password select from at least used button for direct
dialling (-prolong dial time)
Summary of Contents for Smyle - C
Page 1: ...Brave Smyle C Brave Smyle LC Brave Smyle C C User guide Version 2 6 Brave Door Intercom ...
Page 2: ......
Page 12: ...BRAVE user guide 12 2 Installation 2 1 Assembly 2 1 1 Assembly of Brave Smyle front panel ...
Page 17: ...BRAVE user guide 17 Pict 2 Examples of relay connection ...
Page 58: ... JR 2011 13 verze 2 6 X 13 Producer Distributor Sales date ...