BRAVE
– user guide
36
5.4 Time parametres
Parametr Value
Description
Default
51
q
Number of rings before door intercom picks
up incoming call (1-9)
2
q
– number of incoming call rings . Door intercom picks up between rings and
2 sec after detection of
q
– th rings. Number is adjustable from 1 to 9.
Parametr Value
Description
Default
52
d
Maximal call duration (0-9,*,#)
2
d
– maximal time for which door intercom is OFF HOOK.
This time you can prolong by dial character during a
call by phone (* or #
- parametr 42
). Setting of time is
up table.
Parametr Value
Description
Default
53
w
Time between button push (1-9)
2
w
– maximal time [sec] between button push [range 1-9]
normal buttons
-
relay activation
– when time between push of 2 following buttons is
longer than time
w
then code is evaluated incorrectly.
-
Number dial
– when button which we push is first number in password
for relay activation then dial is delayed about this time
w
time[min]
Dial
0,5
0
1 - 9
1 - 9
15
*
30
#