BRAVE
– user guide
38
503
tt
Time of tone duration DTMF (tone) dial
(04-16)
10 (100ms)
504
mm
Time of space duration between DTMF
tones (04-16)
10 (100ms)
505
f
Time of Flash duration (1-6)
1 (100ms)
506
p
Time of pause duration / pause between
numbers
(1-0)
4 (800ms)
tt
–Time of tone duration DTMF (tone) dial is calculated up:
(inserted number) x 10 = tone duration time
[ms]
[range 04-16 tj. 40-160ms]
m
–
Time of space duration between DTMF tones is calculated up:
(inserted number) x 10 =pause duration time
[ms]
[range 04-16 tj. 40-160ms]
f
– Time of Flash duration is calculated:
inserted number x 100 = Flash duration time
[ms]
[range 1-6 tj. 100-600ms]
p
– Time of pause duration is calculated:
inserted number x 100 + 400 = pause duration time
[ms]
[range 1-0 tj. 500-1400ms]
– time
p
is also time of pause between numbers at pulse dialling
Parametr Value
Description
Default
507
uu
Level of sending tone DTMF dial in
[-dBm](04-16)
10
uu
– level of sending tone (DTMF) dial into line, range is -4 to -16dBm. You
insert desired level, uu=04 is -4dBm, uu=10 is -10dBm
Parametr Value
Description
Default
508
p
preemphase DTMF (0/1)
0
509
S
Listening
–in DTMF - level (1-4)
2
p
– preemphase is rate between upper and lower groups of DTMF frequency.
You can select rate 2,2 dB - p=0 (Europe) or rate 3,2dB - p=1 (Australia)
s
– listening –in DTMF level you can select in four levels:
Level of listening in DTMF [dB]
s - dial
-15
1
-9
2
-3
3
+3
4
Summary of Contents for Smyle - C
Page 1: ...Brave Smyle C Brave Smyle LC Brave Smyle C C User guide Version 2 6 Brave Door Intercom ...
Page 2: ......
Page 12: ...BRAVE user guide 12 2 Installation 2 1 Assembly 2 1 1 Assembly of Brave Smyle front panel ...
Page 17: ...BRAVE user guide 17 Pict 2 Examples of relay connection ...
Page 58: ... JR 2011 13 verze 2 6 X 13 Producer Distributor Sales date ...