7
-
22
42hw-201601
Chapter 7 eleCtriC system
3015r(h)/3515r(h)/4015r(h)/F36r(h)/F42r(h) traCtOr
5.1.3 eleCtriC wiriNg
1. If any electric part is malfunctioning, check its
electric wiring.
2. Check if the electric wiring is in contact with
another part, it is peeled off or its contact is
loose.
If it is peeled off, wind insulating tape around it.
3. If water enters the contact area, it can cause
malfunction. Wipe out any moisture and dry it
sufficiently.
4. Try to disconnect and re-connect any related
connectors. Check if a terminal is misaligned or
improperly engaged.
5. Inspect it regularly with the engine running after
every 50 hours of use or after every season even
though there is no apparent sign of damage.
Never attempt to modify electric wirings of the ma-
chine. it can cause a fire.
warNiNg
iNspeCtiON Order FOr eleCtriC sys-
tem aNd CirCuit Failure
Battery
→
Fusible link
→
Fuse
→
ignition relay
→
switch
→
load
▶
Notes
5.1.2 Fuse
Fuse
FusiBle
liNk
slOw-
BlOw
Fuse
6015W702A
6015W703A
6015W704A
If any electric part is malfunctioning, check the fuse
first.
1. Make sure to use the fuse with the specified
capacity.
2. Check if any fusible link is open.
when continuity is detected by touching both terminals
with a tester, it is normal. if continuity is not detected,
replace the part with a new one.
Notes
3. Check that the slow-blow fuse is bolted into the
slow-blow fuse box to the specified torque firmly.
do not replace the fuse with other metal wires or alumi-
num foil. it can lead to electric shock and fire.
if the nut of the slow-blow fuse is not tightened firmly,
it can cause a fire. make sure to tighten it firmly.
CautiON
Summary of Contents for 3015h
Page 6: ......
Page 162: ... BranSOn tractors Co Ltd MEMO ...
Page 172: ... BraNSON tractors Co ltd MEMO ...
Page 278: ... BranSon tractors Co ltd MEMO ...
Page 380: ......
Page 382: ......
Page 384: ......
Page 432: ......
Page 438: ......
Page 447: ...Chapter 8 INDEX ...
Page 454: ... BraNSON tractors Co Ltd MEMO ...