when this check doing to, separates connector
from m terminal.
don’t connect continuously more than 10
second.
•
•
CautIOn
6.7 eLeCtrICaL SyStem
6.7.1 Starter
Item
SpeCIFICatIOn
Output
12V / 2.2kW
Pinion number of teeth
15
No-load voltage
11.5V.
puLL In COIL teSt OF maGnetIC SwItCh(SOLenOId)
▶
The case which connects battery between S-M
terminal, if plunger comes in and the pinion comes
out, the pull in winding is normality. If the pinion
does not come out, replace the magnetic switch.
B
S
K20W2A62
Battery
Start
.
Switch
Basic Wiring Circuit
Basic Solenoid Circuit
Solenoid
Bat.
Cranking
.
Motor
Neutral
.
Safety
.
Switch
Start Switch
Hold-in
.
Winding
pull-in
.
Winding
Contacts
To
.
Motor
Battery
ٻ
K20W2A63
Battery 12V
Starter
Dis-connector
BaSe CIrCuIt dIaGram
SpeCIFICatIOn
CheCk