d0
59
3
2
.f
m
MAINTENANCE MANUAL
BRP-Powertrain
Effectivity: 912 i Series
Edition 1/Rev. 0
00-00-00
Page 21
July 01/2012
Classification
Classification of „On-Condition“ parts at maintenance/repair:
Fig. 4
08219
NOTE:
A negative result means that the actual dimension
F
is within the new
dimension tolerance
D
and the part can be used again.
Example
The hours of operation are indicated with 300 h. The determined percentage of
maximum permissible wear is therefore 36 %.
This part must be replaced because it is excessively worn for only 300 hours of
operation.
New dimension (max.)
B
28,03 mm (1.1035 in.)
Wear limit
C
28,10 mm (1.1062 in.)
Actual dimension
F
28,07 mm (1.1051 in.)
Actual wear
57,1 %
Summary of Contents for Rotax 912 i Series