Effectivity: 912 i Series
Edition 1/Rev. 2
d
059
37.
fm
MAINTENANCE MANUAL
BRP-Powertrain
74-20-00
Page 15
July 01/2014
Fig. 15
DOUBLE IGNITION COIL - INSTALLATION
The double ignition coil is installed and removed
in the same way. The following should be noted.
NOTE:
The red cable is positive (+), the red ca-
ble with the black dash or the black one
is negative (-). Double ignition coils are
la and -!
Fig. 16
Fig. 17
Fig. 18
1. Ignition cable assy.
2. Cable ties
Step
Procedure
1
Plug in the double ignition coil connectors.
1. Double ignition coils
2. Ignition coil connector
(coil 1, coil 2, coil 3, coil 4)
Step
Procedure
2
Fix the double ignition coils with M5x16
Allen screws with plug holders and A5
lock washers.
Tightening torque 5 Nm (44.25 in. lb.).
1. M5x16 Allen screw
2. A5 lock washer
3. Plug holder
Step
Procedure
3
Plug in the connector to the EGT connec-
tor.
NOTE:
Compress the connector with
the EGT connector so that the
spring clip latches in.
1. EGT connector
2. Connector