d0
593
8.
fm
MAINTENANCE MANUAL
BRP-Powertrain
Effectivity: 912 i Series
Edition 1/Rev. 0
75-00-00
Page 13
July 01/2012
WEAR LIMITS
Description
Co
de
Current measurement
value
Tolerance
limit
Tolerance
limit
Measure-
ments
min
max
100 %
50 %
Water pump
Reference to
flat surface
WP01 8.55 mm
0.3366 in.
8.85 mm
0.3484 in.
8.85 mm
0.3484 in.
current
replaced
Distance from impel-
ler
WP02 0.3 mm
0.012 in.
0.5 mm
0.020 in.
0.7 mm
0.028 in.
0.6 mm
0.024 in.
current
replaced