Effectivity: 912 i Series
Edition 1/Rev. 0
d0
593
6.
fm
MAINTENANCE MANUAL
BRP-Powertrain
73-10-00
Page 14
July 01/2012
Fig. 17
Fig. 18.
Fig. 19
Fig. 20
1. M6x14 Allen screw
2. 6.4 washer
3. 12/M6 cable clamp
Step
Procedure
2
Disconnect the 4 ignition coil connectors
on both sides.
NOTE: Use a suitable tool to pull out
the ignition coil plugs.
1. Ignition coil connector
2. Double ignition coils
3. EGT connector
Step
Procedure
3
Carefully pull EGT 1 and EGT 2 (cylinders
1 and 2) out of the locking plate.
4
Press the metal bracket and unplug the
connectors.
1. EGT connector
2. Spring clip
Step
Procedure
5
Loosen the M5x16 Allen screws of the
double ignition coils with washers.
1. M5x16 Allen screw
2. 5.3 washer
3. Plug holder
Step
Procedure
6
Unplug the connectors to the double igni-
tion coils.
7
Remove the double ignition coils