Effectivity: 912 i Series
Edition 1/Rev. 1
d0
667
4.
fm
MAINTENANCE MANUAL
BRP-Powertrain
76-10-00
Page 14
October 01/2013
SITUATION 2:
EXTRACTING LOGS FROM AN IN-
STALLED ECU (ON AIRCRAFT)
Connect Computer with ECU
Fig. 15
NOTE:
If the maintenance interfaces of
LANE A and LANE B are not conduct-
ed separately, the B.U.D.S. Aircraft
Set Sub-D DE9 connector can be
linked to the maintenance interface
directly.
NOTE:
In case of using an USB extension ca-
ble, the length should not exceed
2 meters.
m
WARNUNG
NOTICE
The battery must provide constant voltage thru
the whole extraction process. If this can‘t be en-
sured, an external power supply must be used.
Step
Procedure
1
Connect B.U.D.S. Aircraft Set with the
USB-Port of your computer.
If the device is connected and installed
the RED indicator light should light up.
2
Connect the B.U.D.S. Aircraft Set Sub-D
DE9 connector with the Sub-D DE9 sock-
et of the Y-cable.
3
Connect both Sub-D DE9 sockets of the
Maintenance CAN with the Sub-D DE9
connectors of the Y-cable.
4
Now the setup should be as shown in
.
1. Computer
2. B.U.D.S. Aircraft Set
3. Y-cablel
4. Cockpit (Simulation)
09959