64
|
Boiler circulator
Copyright (optional information)
6 720 643 068 (2011/06)
9
Boiler circulator
9.1
Pump anti-seize protection
The appliance will briefly run the pump at least every 24
hours after its last activation.
9.2
Changing the pump curve of the boiler
pump
The speed of the boiler pump can be changed using the
dial on the pump.
Fig. 64 Pump curve of the boiler pump heating boiler
ZBR..-3A
Fig. 65 Pump curve of the boiler pump combi boiler
ZWB..-3A
Key to Fig. 64 and Fig. 65:
1
Residual head pressure at speed 1
2
Residual head pressure at speed 2
3
Residual head pressure at speed 3 (default setting)
4
Head pressure of the boiler pump by itself (at speed 3)
H
Head pressure in feet of head (m)
Circulating water volume in gallons per minute (l/h)
This function prevents the heating zone pump
from seizing up following longer idle periods.
0
2
5
7
8
1
4
3
6
15
20
25
10
5
0
H / ft
.
V / gpm
1
2
3
4
400
800
1200
1600
200
600
1000
1400
7
0
6
5
4
3
2
1
0
H / m
.
V / l/h
6 720 641 933-59.1O
1
2
3
4
In order to save as much energy as possible
and keep any water circulation noises to a
minimum, select the lowest possible pump
speed.