Making the electrical connections
|
53
6 720 643 068 (2011/06)
Copyright (optional information)
6.2.2
Connecting the outdoor temperature sensor
B
Connecting the controls automatically establishes the
internal communications BUS connection (
Æ
see
installation instructions for the controls).
B
Punch out plastic insert.
B
Connect cable of the outdoor temperature sensor
according to Fig. 37.
B
Insert cable for the outdoor temperature sensor.
B
Secure the cable with the strain relief.
Fig. 37 Electrical wiring outdoor temperature sensor
6.2.3
Connecting the DHW tank temperature sensor
(only heating boiler ZBR..-3A)
Wire the DHW tank temperature sensor directly to the
appliance terminals. The sensor is provided with the
appliance.
Do not exceed a sensor cable length of 33 feet (10 m).
B
Punch out plastic insert.
B
Plug connector into the circuit board.
B
Insert the cable of the DHW tank temperature sensor.
B
Secure the cable with the strain relief.
Fig. 38 Electrical connections DHW tank temperature
sensor
6 720 641 933-35.1O
A
F
6 720 641 933-73.1O