88
|
Inspection and maintenance
Copyright (optional information)
6 720 643 068 (2011/06)
14.2 Checklist for inspection and maintenance
B
Use this form to guide you through the service and maintenance procedure. Fill out each step according to the findings
and work performed.
Date
Æ
1
Latest fault code from service function
6.A
(
Æ
page 82).
2
Fresh water inlet filter (Combi boiler ZWB appliances
only) (
Æ
page 82).
3
Visual inspection of the combustion air pipes and vent
pipes.
4
Dynamic gas pressure (
Æ
page 78).
inches
W.C.
(mbar)
5
Gas-air ratio at min./max. nominal output
(
Æ
page 76).
min. %
max. %
6
Gas and water-side leak test (
Æ
page 51).
7
Inspect electrodes (
Æ
page 83).
8
Inspect heat exchanger block (
Æ
page 84).
9
Check burner (
Æ
page 84).
10
Inspect diaphragm in mixer unit (
Æ
page 86).
11
Clean condensate trap (
Æ
page 86).
12
With the system depressurized, check the
expansion vessel pre-charge pressure vs. the
static head of the heating system.
psi
(bar)
13
Check the heating system filling pressure.
psi
(bar)
14
Inspect electrical wiring for damage.
15
Check settings of the heating control.
16
Check set service functions according to commissioning
report (
Æ
page 97).
Tab. 34 Maintenance and inspection checklist