24
|
Information about the appliance
Copyright (optional information)
6 720 643 068 (2011/06)
3.13 Technical data heating boiler ZBR35-3A...
Unit
NG
LPG (propane)
Output
Maximum nominal output (P
max
) 104/86 °F (40/30 °C)
BTU/hr (kW)
122,800 (36.0)
122,800 (36.0)
Maximum nominal output (P
max
) 122/86 °F (50/30 °C)
BTU/hr (kW)
121,800 (35.7)
121,800 (35.7)
Maximum nominal output (P
max
) 176/140 °F (80/60 °C)
BTU/hr (kW)
116,700 (34.2)
116,700 (34.2)
Max. nominal thermal load (Q
max
) heating (H
i
) 180/79 °F (82/26 °C)
BTU/hr (kW)
118,700 (34.8)
118,700 (34.8)
Max. nominal thermal load (Q
max
) heating (H
s
) 180/79 °F (82/26 °C)
BTU/hr (kW)
131,900 (38.6)
129,100 (37.8)
Min. nominal output (P
min
) 104/86 °F (40/30 °C)
BTU/hr (kW)
35,100 (10.3)
46,100 (13.5)
Min. nominal output (P
min
) 122/86 °F (50/30 °C)
BTU/hr (kW)
34,800 (10.2)
45,700 (13.4)
Min. nominal output (P
min
) 176/140 °F (80/60 °C)
BTU/hr (kW)
31,700 (9.3)
42,000 (12.3)
Min. nominal thermal load (Q
min
) heating (H
i
) 180/79 °F (82/26 °C)
BTU/hr (kW)
32,400 (9.5)
42,700 (12.5)
Min. nominal thermal load (Q
min
) heating (H
s
) 180/79 °F (82/26 °C)
BTU/hr (kW)
36,000 (10.5)
46,400 (13.6)
Max. nominal thermal load (Q
max
) tank (H
i
) BTU/hr
(kW)
118,700 (34.8)
118,700 (34.8)
Max. nominal thermal load (Q
max
) tank (H
s
)
BTU/hr (kW)
131,900 (38.6)
129,100 (37.8)
Min. nominal thermal load (Q
min
) tank (H
i
)
BTU/hr (kW)
32,400 (9.5)
42,700 (12.5)
Min. nominal thermal load (Q
min
) tank (H
s
)
BTU/hr (kW)
36,000 (10.5)
46,400 (13.6)
Gas connection value
Natural Gas – H
s
= 1,010 BTU/ft
3
(37.3MJ/m
3
)
ft
3
/hr (m
3
/h)
130 (3.7)
–
Liquid Propane Gas – H
D-S
= 2,500 BTU/ft
3
(93.1MJ/m
3
)
ft
3
/hr (m
3
/h)
– 52
(1.5)
Permissible inlet gas pressure
NG
in. W.C. (mbar)
3.5-10.5" (8.7-26.1)
–
LPG (propane)
in. W.C. (mbar)
– 8-13"
(19.9-32.3)
Calculation values for calculating cross-section to EN 13384
Flue gas mass flow at maximum/minimum nominal output
gps
15.7/4.5
15.2/5.6
Flue gas temperature 176/140 °F (80/60 °C) at maximum/minimum
nominal heat input
°F ( °C)
162/135 (72/57)
162/135 (72/57)
Flue gas temperature 104/86 °F (40/30 °C) at maximum/minimum
nominal heat input
°F ( °C)
127/91 (53/33)
127/91 (53/33)
CO
2
at max. nominal output
%
9.4
11.0
CO
2
at minimum nominal output
%
8.6
10.4
Condensate
Max. condensate quantity (t
R
= 86 °F (30 °C))
gph (l/h)
0.8 (3.1)
0.8 (3.1)
pH level, approx.
4.8
4.8
Tab. 6 Technical data heating boiler ZBR35-3A...