background image

 

 

 
 
 
 
 
 
 

Installation & Manual 
 

 

 Boiler With Solid Fuel 
 

Model T-30 / T-40

 

 
               
 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

TR

 

Summary of Contents for T-30

Page 1: ...Installation Manual Boiler With Solid Fuel Model T 30 T 40 TR R...

Page 2: ...M 4 4 THE PROCEDURES AND SECURITY PRECAUTIONS BEFORE USING THE FLOOR HEATING 4 5 ELECTRONIC CONTROL SYSTEM INSTALLATION AND USE 7 5 1 INSTALLATION 7 5 2 USE OF ELECTRONIC CONTROL SYSTEM 7 5 3 FEATURES...

Page 3: ...on of pressure due to the water vapor in the boiler 2 BOILER SPECIFICATIONS T 30 FUEL TYPE SOLID FUEL HEAT POWER 30 KW BOILER INPUT OUTPUT INCH 1 OPERATION PRESSURE 1 2 BAR FLUE PIPE DIAMETER 150 mm F...

Page 4: ...way the hot water in the boiler is felt in the radiator in less time Note The diameters of the input and output pipes of the last 4 mtul radiators can be 3 4 metal pipe or 3 4 internal diameter plast...

Page 5: ...elbow and 2 pieces of pipe 6 Solid fuel floor heating boilers as seen in FIGURE 2 the inlet and outlet of the radiator must be connected to the main pipes in the heating system with the connection par...

Page 6: ...the vapor output water discharge on the expansion tank must not be closed 12 The expansion tank steam output shown in FIGURE 2 used to throw out the vapor from our boiler By drawing a line from the st...

Page 7: ...When the electronic control system is installed and the power cable is plugged the temperature and the circulation pump are visible on the display of the electronic control system 2 When pressing one...

Page 8: ...when the boiler temperature falls below the set value the circulation pump automatically deactivates and stop running The lowest limit must be 55 C When the temperature drops below 55 C condensation...

Page 9: ...5 C in extreme cold conditions the circulation pump activates and does not allow any freezing in the installation and boiler through circulating the heating water inside the boiler and the installatio...

Page 10: ...at the remaining air in the boiler and in the installation is pumped into the expansion tank by running the pump for 10 minutes Note The procedures listed in Articles 3 and 4 above should be made in t...

Page 11: ...n damage the installation and boiler Our companyisnotresponsibleforthesedamages 8 Solidfuelboilersshouldnotbeloadedwithmorethanthecapacityoffuel Ourboilercan bedamagedduetoexcessivefuelloading 9 Anadd...

Page 12: ...uct our company will try to repair this damage as soon as possible within the warranty period or it will replace the problematic part Only spare parts approved or supplied by the manufacturer must be...

Reviews: