AutoDome Easy II
Installing a Surface Mount | en
27
Bosch Security Systems, Inc.
Installation Manual
F.01U.164.478 | 2.0 | 2010.02
Figure 4.7
Attach surface mount to ceiling
11. Route the external wires through the conduit and into the
Surface Mount Junction Box.
12. Secure the mounting plate to the Surface Mount Junction
Box with the three (3) M4 – .7 x 8 Phillips pan head
machine screws.
Figure 4.8
Install the Mounting Plate
CAUTION!
All wires for installation applications must be routed through a
grounded conduit.
1
Junction Box Holes
2
Cable Hole (40 mm maximum); Crescent Shape
40
.0 m
m
1.57 in.