Bosch Security Systems, Inc.
A.2.1
Hardware Configuration
The AutoDome Easy II is configured from the factory for RS-485
operation in
Pelco Protocol Mode
.
1.
Connect the controller's TX terminals to the AutoDome
Easy II's TxD terminals. See the AutoDome Easy II Modular
Camera System Installation Manual for complete wiring
instructions.
2.
Pan or tilt the keyboard joystick to confirm that control has
been established to the AutoDome Easy II (approximately
five (5) seconds).
A.2.2
Pelco Keyboard Commands
Pelco control commands are composed of a sequence of two
(2) keyboard inputs with the following convention: 1) a
Command Number
and 2) a
Function
key input.
The AutoDome Easy II uses the
PRESET
command key to save
and recall presets (pre-positions) 1 through 99.
NOTICE!
To save a preset, enter the desired number and hold the
PRESET
key for approximately two (2) seconds. To recall a
preset, enter the desired preset number (or command) and
momentarily press and release the
PRESET
key.