12
en | Safety
AutoDome Easy II
F.01U.164.478 | 2.0 | 2010.02
Installation Manual
Bosch Security Systems, Inc.
Environmental statement -
Bosch has a strong commitment to
the environment. This unit has been designed to respect the
environment as much as possible.
Electrostatic-sensitive device -
Take proper CMOS/MOS-FET
handling precautions to avoid electrostatic discharge.
NOTE: You must wear grounded wrist straps and observe
proper ESD safety precautions when handling the electrostatic-
sensitive printed circuit boards.
Fuse rating -
For security protection of the device, the branch
circuit protection must be secured with a maximum fuse rating
of 16 A. This must be in accordance with
NEC800 (CEC Section
60)
.
Grounding and polarization -
This unit may be fitted with a
polarized alternating current line plug (a plug with one blade
wider than the other blade). This safety feature allows the plug
to fit into the power outlet in only one way. If unable to insert
the plug fully into the outlet, contact a locally certified
electrician to replace the obsolete outlet. Do not defeat the
safety purpose of the polarized plug.
Alternatively, this unit may be fitted with a 3-pole grounding
plug (a plug with a third pin for earth grounding). This safety
feature allows the plug to fit into a grounded power outlet only.
If unable to insert the plug into the outlet, contact a locally
certified electrician to replace the obsolete outlet. Do not
defeat the safety purpose of the grounding plug.
Outdoor signals -
The installation for outdoor signals, especially
regarding clearance from power and lightning conductors and
transient protection, must be in accordance with
NEC725
and
NEC800 (CEC Rule 16-224
and
CEC Section 60)
.
Moving -
Disconnect the power before moving the unit. Move
the unit with care.
PoE (Indoor models only) -
Never supply power via the
Ethernet connection (PoE) when power is already supplied via
the power connector nor to an outdoor model.
Permanently connected equipment -
Incorporate a readily
accessible disconnect device in the building installation wiring.