122
en | Troubleshooting
AutoDome Easy II
F.01U.164.478 | 2.0 | 2010.02
Installation Manual
Bosch Security Systems, Inc.
16.1
AutoDome Easy II Operation and Control
Problem
Solution
No video
–
Check that the Red LED (power) is on by removing the unit
from its mount and looking on top of the unit. This LED
indicates video from the camera.
Red LED on AutoDome Easy II CPU Module
If the Red LED is on, then:
–
Try cycling the AutoDome Easy II power off and on.
If the Red LED is off, then:
–
Check that the mains power to the power supply is on.
If O.K., then:
–
Check that there is 24 V output from the transformer.
If O.K., then:
–
Check the integrity of all wires and mating connectors to
the AutoDome Easy II.
No
camera
control
–
Ensure that the keyboard and monitor are set to the correct
(same) camera number.
If O.K., then:
–
Check that the camera address is properly set. Enter
ON
-
997
-
ENTER
to display the camera address.
If address is not set or is incorrect, then:
–
Set the camera address using FastAddress (
ON
-
998
-
ENTER)
.
If O.K., then:
–
Check that the Yellow LED, located on the top of the
AutoDome Easy II unit, turns on when receiving pan/tilt
commands from the controller keyboard. The Yellow LED
indicates data is being received.