92
en | Configuring the HD Conference Dome
HD Conference Dome
F.01U.265.806 | 1.0 | 2012.03
Installation Manual
Bosch Security Systems, Inc.
2.
If you select the
Custom
option, additional fields are
displayed where you can specify the exact position
(
Position (XY)
).
3.
In the
Position (XY)
fields, enter the values for the desired
position.
Display milliseconds
If necessary, you can also display milliseconds. This information
can be useful for recorded video images; however, it does
increase the processor's computing time. Select
Off
if you do
not need to display milliseconds.
Alarm mode stamping
Select
On
to display a text message overlay in the image in the
event of an alarm. It can be displayed at a position of your
choice that you can then specify using the
Custom
option. Or it
can be set to
Off
for no overlay information.
1.
Select the desired option from the list.
2.
If you select the
Custom
option, additional fields are
displayed where you can specify the exact position
(
Position (XY)
).
3.
In the
Position (XY)
fields, enter the values for the desired
position.
Alarm message
Enter the message to be displayed in the image in the event of
an alarm. The maximum text length is 31 characters.
Title OSD
Select
On
to continuously display sector or shot title overlays in
the image. Select
Momentary
to display sector or shot title
overlays for a few seconds. OSD titles can be displayed at a
position of your choice, or it can be set to
Off
for no overlay
information.
1.
Select the desired option from the list.
2.
Specify the exact position (
Position (XY)
).
3.
In the
Position (XY)
fields, enter the values for the desired
position.