126
en | Configuring the HD Conference Dome
HD Conference Dome
F.01U.265.806 | 1.0 | 2012.03
Installation Manual
Bosch Security Systems, Inc.
4.
Click the
Load...
button to load a saved profile. A new
window opens in which you can select the profile file and
specify where to save the file.
VCA configuration
Select one of the profiles here to activate it or edit it.
You can rename the profile.
1.
To rename the file, click the icon to the right of the list field
and enter the new profile name in the field.
2.
Click the icon again. The new profile name is saved.
Alarm status
The alarm status is displayed here for information purposes.
This means you can check the effects of your settings
immediately.
Analysis type
Select the required analysis algorithm. By default, only
is available – this offers a motion detector and
essential recognition of tampering.
Metadata is always created for a video content analysis, unless
this was explicitly excluded. Depending on the analysis type
selected and the relevant configuration, additional information
CAUTION!
Do not use any special characters, for example
&
, in the name.
Special characters are not supported by the system's internal
recording management and may therefore result in the Player or
Archive Player being unable to play back the recording.
NOTICE!
Additional analysis algorithms with comprehensive functions
such as IVMD and IVA are available from Bosch Security
Systems, inc.
If you select one of these algorithms, you can set the
corresponding parameters here directly. You can find
information on this in the relevant documents on the product
CD supplied.