Personal injury or property damage by inter‐
rupting or connecting live lines!
WARNING
Interrupting or connecting live lines may cause unpredictable dangerous sit‐
uations or lead to property damage. Therefore:
●
Connect and disconnect plug-in connectors only when they are dry and
de-energized.
●
During operation of the installation, all plug-in connectors must be
locked.
Risk of short circuit caused by liquid coolant
or lubricant!
WARNING
Short circuits of live lines may cause unpredictable dangerous situations or
lead to property damage. Therefore:
●
Provide exposed mating sides of power plug-in connectors with safety
caps when installing or replacing drive components, if you cannot ex‐
clude that they might be moistened with liquid coolant or lubricant.
9.6.2
Notices
The motor cable is a hybrid cable in which the communication line has been
integrated. Only the hybrid cable by Rexroth can ensure the function. It is
supplied as ready-made cable. The outgoing direction of the hybrid cable
cannot be changed subsequently!
Risk of damage by subsequently changing
the outgoing direction of the hybrid cable!
NOTICE
Do not try to reverse the cable outgoing direction of a ready-made connector!
The flexible leads in the connector have individual lengths for each outgoing
direction.
Risk of damage by leakage of the connection
points!
NOTICE
If vibrations affect the hybrid cable: Install strain relief near the connection
points (X103.1, X103.2) so that the connectors are not affected by high vibra‐
tion loads. This can avoid possible leakage (entering liquid).
When ordering the ready-made hybrid cables, always indicate the desired
outgoing direction: See
chapter 5.8.1 "RKH hybrid cable incl. communica‐
tion, technical data" on page 106
Ready-made hybrid cables have been coded in such a way that X103.1 and
X103.2 cannot be interchanged when connecting the cables.
9.6.3
Electrical interfaces
Overall connection diagram
At the first KSM/KMS, always plug the hybrid cable RKH in con‐
nection point X103.1.
Always terminate the unassigned connection at the last
KSM/KMS with a terminal connector RHS.
DOK-INDRV*-KCU02+KSM02-PR03-EN-P
Bosch Rexroth AG
259/337
Rexroth IndraDrive Mi Drive Systems with KCU02 KSM02, KMS02/03, KMV03, KNK03
Mounting and installation