10.3
HAS02, shield connection
For proper and correct installation of KSM and KCU, use the RKH
hybrid cable and the HAS02.1-015-NNN-NN accessory.
The HAS02.1-015-NNN-NN accessory connects the shield of the hybrid ca‐
ble to the housing of the KCU drive connection box.
1
Shield connection
2
Clip
3
Hybrid cable
4
Shield of hybrid cable
Fig. 10-1:
Shield connection
●
Mount the shielding plate (1) to the drive connection box KCU according
to the desired outgoing direction of the hybrid cable (horizontal or 45°).
●
According to the diameter of the hybrid cable (3), the shielding plate (1)
provides two supports (12–18 mm or 19–30 mm). Fix the hybrid ca‐
ble (3) to the corresponding support with a clip (2). Make sure that the
shield (4) of the hybrid cable has good contact with the shielding plate
(1).