H14
Color / flashing pattern
1)
Significance
Measures
Green
●
AH (Drive Halt)
●
AF (Drive in control)
●
Lb (supply unit in rectifier
mode)
●
LB (supply unit in voltage
control)
●
I LB (supply unit in current
control)
-
Flashing red-green
Bus state (e.g., not active,
pre‑operational, …)
-
Loader active
-
Flashing red
Firmware update error
Repeat firmware update
●
All warnings
●
Command errors
Read detailed state via "S‑0‑0095,
Diagnostic message"
All errors (except F4xxx)
Read detailed state via "S‑0‑0095,
Diagnostic message" and carry out
service function
Communication error (F4xxx)
If necessary, read detailed state via
"S‑0‑0095, Diagnostic message"
Red
Booting phase
Wait until booting phase is over
(approx. 2 minutes)
System error (F9xxx)
●
Switch off and on; replace
hardware, if necessary
●
Check whether programming
module has been plugged
1)
Flashing pattern: One square corresponds to a duration of
250 ms; the arrow marks the end of a cycle; abbreviations on
the squares: GN = LED permanently lit green, RD = LED per‐
manently lit red, ‑‑ = LED is off
Tab. 11-2:
H14 LED displays
Bosch Rexroth AG
DOK-INDRV*-KCU02+KSM02-PR03-EN-P
298/337
Rexroth IndraDrive Mi Drive Systems with KCU02 KSM02, KMS02/03, KMV03, KNK03
Commissioning, operation, diagnostics and maintenance