Braking resistor
Integrated braking resistor data
Description
Symbol
Unit
KMV03.1R-B0007-P-D7-ET-NNNN
Braking resistor continuous power
P
BD
kW
0.15
Braking resistor peak power
P
BS
kW
12.00
Nominal braking resistor
R
DC_Bleed‐
er
ohm
60
Braking resistor switch-on thresh‐
old – independent of mains volt‐
age
1)
U
R_DC_On_f
V
820
Regenerative power to be absor‐
bed
W
R_max
kWs
7.50
Cooling of integrated braking re‐
sistor
Base plate (Coldplate)
Last modification: 2016-02-11
1)
Factory setting
Tab. 5-15:
KMV - Integrated braking resistor data
Bosch Rexroth AG
DOK-INDRV*-KCU02+KSM02-PR03-EN-P
98/337
Rexroth IndraDrive Mi Drive Systems with KCU02 KSM02, KMS02/03, KMV03, KNK03