Locking pins at connectors and
connection points
A
Locking pins at connection points X103.1 and X103.2
B
Locking pin at connector of hybrid cable
Fig. 5-28:
Locking pins
Locking pins at connectors and connection points ensure that hybrid cables
run in the right direction. It is not allowed to subsequently invert the direction
of a hybrid cable by removing the locking pins. Otherwise, the signals for E-
Stop and safety technology would not be valid.
When mounting hybrid cables in cable ducts or flexible cable tracks, make
sure that the direction of the hybrid cables is correct.