Rexroth IndraDrive C HCS03.1
Electrical Data
6-7
DOK-INDRV*-HCS03.1****-PR02-EN-P
6.5
Power Section - Inverter
Designation
Symbol
Unit
HCS03.1E-
W0070
HCS03.1E-
W0100
HCS03.1E-
W0150
HCS03.1E-
W0210
output voltage
fundamental
component of
voltage
U
out
with open-loop
U/f ctrl
with closed-
loop oper.
V
V
UDC * 0,95 / 1,41
UDC * 0,9 / 1,41
output frequency
range
- at f
s
= 4 kHz
– at f
s
= 8 kHz
– at f
s
= 12 kHz
– at f
s
= 16 kHz
f
out
Hz
0 ... 400
0 ... 800
0 ... 1200
0 ... 1600
0 ... 400
0 ... 800
0 ... 1200
0 ... 1600
0 ... 400
0 ... 800
0 ... 1200
0 ... 1600
0 ... 400
0 ... 800
0 ... 1200
0 ... 1600
maximum output
current
I
out_max (4 kHz)
I
out_max (8 kHz)
I
out_max (12 kHz)
I
out_max (16 kHz)
A
70
50
36
28
100
70
50
40
150
100
75
60
210
150
100
75
continuous output
current or rated
current
I
out_cont (4 kHz)
I
out_cont (8 kHz)
I
out_cont (12 kHz)
I
out_cont (16 kHz)
A
45
33
24
18
73
50
37
27
95
66
48
37
145
100
72
54
continuous output
current or rated
current
at electric rotational
frequency 0 Hz
I
out_cont (4 kHz)
I
out_cont (8 kHz)
I
out_cont (12 kHz)
I
out_cont (16 kHz)
A
70
50
36
28
100
70
50
40
150
100
75
60
210
150
100
75
Fig. 6-10:
Data power section - inverter
Note:
Depending on the electric rotational frequency, the output
current is reduced for thermal protection of the power section.
The output current is reduced when the value of the electric
rotational frequency falls below 4 Hz.
Summary of Contents for Rexroth IndraDrive C HCS03.1
Page 6: ...IV Contents Rexroth IndraDrive C HCS03 1 DOK INDRV HCS03 1 PR02 EN P ...
Page 12: ...1 6 Indroduction Rexroth IndraDrive C HCS03 1 DOK INDRV HCS03 1 PR02 EN P ...
Page 30: ...4 4 Identification Rexroth IndraDrive C HCS03 1 DOK INDRV HCS03 1 PR02 EN P ...
Page 38: ...5 8 Mechanical Data Rexroth IndraDrive C HCS03 1 DOK INDRV HCS03 1 PR02 EN P ...
Page 72: ...8 6 Replacing Devices Rexroth IndraDrive C HCS03 1 DOK INDRV HCS03 1 PR02 EN P ...
Page 84: ...11 4 Index Rexroth IndraDrive C HCS03 1 DOK INDRV HCS03 1 PR02 EN P ...
Page 85: ......